![Avaya G600 Скачать руководство пользователя страница 128](http://html1.mh-extra.com/html/avaya/g600/g600_installing-manual_3027010128.webp)
128
Installing the Avaya™ S8700 Media Server with Avaya™ MCC1 or SCC1 Media Gateway
Connect the MDF to Stations and PSTN
May 2003
Three-pair circuits can also be run directly from the equipment room MDF to a 356A adapter as
shown in
‘‘3-Pair to 4-Pair Circuit Distribution and Connectivity’’ on page 131
. Four-pair
station cables connect the adapter to the information outlets. Four-pair station cables can be run
directly from a satellite location to the information outlets as previously described.
NOTE:
Bridged taps are not allowed on any part of the station wiring.
4-Pair Circuit Distribution and Connectivity
Figure notes
1
Part of Main Distribution
Frame (MDF)
2
3-Pair Connecting Blocks
3
4-Pair Connecting Blocks
4
Purple Field
5
Blue Field
6
Patch Cord or Cross-Connect
Jumpers
7
To Media Gateway (3-Pair Modularity)
8
B25A Cable
9
Connectorized (Staggered Finger) Multiple
25-Pair Cable
10
258A or BR2580A Adapter
11
Information Outlet
12
4-Pair Circuit
13
DIW Station Cable (D-Inside Wire)
2
3
8
8
4
9
7
6
1
12
12
11
10
13
r764797a CJL 031396
Содержание G600
Страница 1: ...Installing the Avaya S8700 Media Server with an Avaya G600 Media Gateway Release 1 3 Issue 3 May 2003 ...
Страница 20: ...20 DocumentTitle Variable Download License and Avaya Authentication Files May 2003 ...
Страница 273: ...273 Installing the Avaya S8700 Media Server with Avaya G600 Media Gateway Index May 2003 Z ZD8AJ adapter 125 ...
Страница 274: ...274 Installing the Avaya S8700 Media Server with Avaya G600 Media Gateway Index May 2003 ...