HEX display output
Description
Startup codes
FAIL
CallPilot failed the start sequence and cannot accept
calls. Review the event log for further information.
MIN
A minor alarm occurred. Review the event log for
further information.
MAJ
A major alarm occurred. Review the event log for
further information.
CRI
A critical alarm occurred. Review the event log for
further information.
???
An alarm of unknown severity occurred. This error
should not occur on a properly installed system. The
severity of this event is treated as higher-than-
critical, contact your Avaya technical support
representative.
DOWN
The operating system shut down. When the power
status LED is on, it is safe to remove the 202i server
from the switch.
If you perform a cold restart by pressing Reset on the
202i server faceplate, or by removing and then
reinserting the 202i server in the switch, the start
sequence starts at stage 1, described in
on page 27.
If you perform a warm restart by selecting Restart on
the operating system shutdown menu, the start
sequence begins at stage 9, described in
on page 27. However, the
HEX display behaves as follows:
• The DOWN message remains displayed until the
operating system start sequence begins.
• The DOWN message does not scroll.
Section B: Startup diagnostics
In this section
Troubleshooting your Avaya CallPilot
®
system
24 Avaya CallPilot 202i Server Maintenance and Diagnostics
December 2010