background image

 

AVADY POOL  - 

 9, Chaussée Jules César,  Bâtiment 4 Hall 406 - 95520 OSNY – France 

Tel : +33 (0)1 34 48 16 03 Fax : +33 (0)1 78 76 73 95 Email : 

[email protected]

  Web : 

www.avadypool.com 

Installation and operating instructions are included with the product when purchased new. They can also be found on our website.

 

NOTES 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание POOLeasy pH

Страница 1: ...INSTRUCTIONS AND USER MANUAL POOLeasy pH POOLeasy Rx Power at the service of water...

Страница 2: ...LLATION AND RECOMMENDATIONS 6 4 1 Recommendations 6 4 2 Principle of hydraulic and electrical installation 7 4 2 1 Case of a POOLeasy pH connected to a permanent power supply and filtration detection...

Страница 3: ...ings in pH mode 20 5 2 2 POOLeasy settings in REDOX mode 21 5 2 3 Guide for setting activation time for the pH or Redox pumps 22 5 2 4 Overdose alarm settings 22 5 3 POOLeasy standby mode 23 5 4 POOLe...

Страница 4: ...out by qualified and authorized personnel The manufacturers decline all responsibility for the consequences of failure to respect this rule 1 1 2 Warranty extension for the sensor Applicable conditio...

Страница 5: ...e characteristics of the pump and it proper use The manufactures can not be held responsible for damage deriving for improper erroneous or unreasonable use of the pump 1 4 RISKS After unpacking the pu...

Страница 6: ...5 TOXIC AND OR DANGEROUS LIQUID DOSAGE To avoid risk from contact with hazardous liquids or toxic fumes always adhere to the notes in this instruction manual Follow the instructions of the dosing liqu...

Страница 7: ...onfiguration 2 1 Description of parts The complete list of accessories delivered with the equipment is given below All the parts will be necessary for the correct operation of your unit A1 pH4 pH7 cal...

Страница 8: ...ns 3 or 4 allows the modification of the setpoint value The button allows an increase in the numerical value or scrolling the list of selections The button allows a decrease in the numerical value or...

Страница 9: ...pH 9 REDOX mode measurement 900 mV Check pool water parameters TAC 100 mg L FILTR DISABLED The filtration pump is not operating The POOLeasy unit is therefore paused Refer to Section 5 2 1 to disable...

Страница 10: ...sor holder placed on the main pipe prior to any salt chlorinator cell H or after all pool accessories heating etc This injector sensor holder is the support for the measurement electrode and injection...

Страница 11: ...binet for control of pool circulation pump E Pool water circulation pump F Pool G Pool filter H 2 in 1 sensor holder for the injection of disinfectant and support of the Redox sensor I Electrical cabl...

Страница 12: ...ark the holes and drill to the diameter indicated on the plugs Secure the bracket Slide the pump into the bracket 1 Remove the sensor s protective cap and keep it to re use it for the winter shutdown...

Страница 13: ...10 STEP 4 Probe holder preparation 4 2 Mount the o ring H under the probe holder B 4 1 Remove the cap storage Min 15 Min 15 1 2...

Страница 14: ...11 STEP 5 Place the probe holder B by inserting the injection tube in the direction of the waterflow 1 2 3 Q...

Страница 15: ...12 STEP 6 Securization on the pipe 1 50 pipe 2 63 pipe K C L K C L O...

Страница 16: ...13 Vertical...

Страница 17: ...when the filtration pump is on In this way the POOLeasy unit will be authorised to dose 2 Connect the power supply cable equipped with its plug in a domestic power supply socket It is preferable that...

Страница 18: ...n for 5 SECONDS CALIBRATING pH 7 pH 7 25 90s QUALITY 100 pH 4 0 PRESS OK RINCE PROBE PUT IN PH 4 MOVE IR AROUND STOP TOUCHING LET INSIDE pH 7 0 PRESS OK Caution before soaking the sensor in the pH 4 s...

Страница 19: ...THE 475 mV SOLUTION SHAKE LEAVE INSIDE WITHOUT TOUCHING pH 8 5 PRESS OK Hold down the CAL OK button for 5 SECONDS CALIBRATION mV 475 462 pH 90s QUALITY 100 475 pH PRESS OK Tip PRESS THE ESC KEY AT AN...

Страница 20: ...17 STEP 10 Installation of the short probe 80mm G J 1 2 3...

Страница 21: ...ith acid your unit is ready for use without further preparation Otherwise please refer to the following sections to adjust the advanced parameters as a function of your needs Cut Tube J to connect the...

Страница 22: ...DOWN THE MENU ESC BUTTON for 5 seconds to enter the menu LANGUAGE FRENCH Language selection Once inside the menu use the and buttons to scroll between the different choices and the CAL OK button to va...

Страница 23: ...ctivation time in steps of pH 0 1 for correction OVERDOSING ALARM 0 5 L 4 Hrs Setting of overdosing alarm refer to Section 5 2 4 MEASUREMENT ADJUST 0 00 pH Adjustment of the displayed value by or pH 0...

Страница 24: ...3 L h OVERDOSING ALARM 0 5 L 4 Hrs Setting of overdosing alarm refer to Section 5 2 4 MEASUREMENT ADJUST 0 mV Adjustment of the displayed value by or 30 mV CAUTION improper use of this parameter may...

Страница 25: ...allows dynamic monitoring of any potential overdosing HOLD DOWN THE MENU ESC KEY for 5 seconds Press CAL OK several times 4 times until you enter the OVERDOSE ALARM menu OVERDOSING ALARM 0 05 L 4 Hrs...

Страница 26: ...oint desired pH To dose less the POOLeasy inserts increasingly long pauses between increasingly short operating times This is why the unit often has the pump stopped when the displayed value is not th...

Страница 27: ...24 7 Maintenance 7 1 Replacement of the peristaltic tube 7 2 Maintenance of chlorine injection valve Fig 13 Clean the injector tube from chlorine deposit with acid water or replace PVC tube...

Страница 28: ...s of water the measurement will deteriorate A thin layer of limescale together with other elements present in the pool water will be deposited on the sensitive elements of the sensor To mitigate this...

Страница 29: ...26 7 3 2 Installation of a long probe 120mm J G P 1 2 3...

Страница 30: ...g solution This allows the removal of any deposits formed during its use in pool water The sensor must be filled to 1 3 with AYACSOLSTK01 storage solution and the protective cap placed on the sensor s...

Страница 31: ...mplete 2 in 1 sensor holder 9 AYFA00004 Sensor holder cap 10 AYAC100020 Strainer 11 AYAC100122 Clip 12 AYAC100010 Crystal PVC tube 4x6 13 AYAC02C001 pH4 calibration solution AYAC02C002 pH7 calibration...

Страница 32: ...406 95520 OSNY France Tel 33 0 1 34 48 16 03 Fax 33 0 1 78 76 73 95 Email contact avadypool com Web www avadypool com Installation and operating instructions are included with the product when purchas...

Отзывы: