5.2.1 POOLeasy settings in pH mode
To set your POOLeasy in pH mode, refer to the previous section (5.0)
MEASUREMENT TYPE
pH
PUMP FLOWRATE
1.5 L/h
Flowrate setting for pump on the unit
(1.5 or 3 L/h)
Factory setting
No. of calib. points
2
Setting of number of calibration points (1 or 2). The
single calibration point is at pH 7.
DOSING MODE
ACID (pH-)
Choice of reagent for dosing between
acid (pH-) and alkaline (pH+)
PUMP ACT. TIME
20 s/0.1pH
Setting of pump activation time in
steps of pH 0.1, for correction
OVERDOSING ALARM
0.5 L/4 Hrs
Setting of overdosing alarm: refer to
Section 5.2.4
MEASUREMENT
ADJUST
0.00 pH
Adjustment of the displayed value by + or – pH 0.40.
CAUTION: improper use of this parameter may
result in erroneous dosing.
PUMP FLT INPUT
ON
Allows the enabling/disabling of the 230V input
corresponding to the enabling of the filtration
pump. It is the input that corresponds to cable "
i
"
defined in Step 13 of the installation procedure.
FACTORY SETTINGS
NO
Allows unit reinitialization.
By selecting YES, a confirmation will follow.
Return to language selection menu.
Press
MENU/ESC
to exit the menu.
Содержание POOLeasy pH
Страница 1: ...INSTRUCTIONS AND USER MANUAL POOLeasy pH POOLeasy Rx Power at the service of water...
Страница 14: ...11 STEP 5 Place the probe holder B by inserting the injection tube in the direction of the waterflow 1 2 3 Q...
Страница 15: ...12 STEP 6 Securization on the pipe 1 50 pipe 2 63 pipe K C L K C L O...
Страница 16: ...13 Vertical...
Страница 20: ...17 STEP 10 Installation of the short probe 80mm G J 1 2 3...
Страница 29: ...26 7 3 2 Installation of a long probe 120mm J G P 1 2 3...