Before carrying out any service on the item, check:
1.
Disconnect the plug from the mains.
2.
Relieve all the pressure from the pump head or the injection tube.
3.
Drain or flush all dosing liquid from the pump head. This operation can also be done with the
pump disconnected from the plant by turning the pump upside-down for 10 seconds and
without connecting the tubing to the nipples.
In event of possible losses on the hydraulic system of the pump (breakage of the O-ring, the valves or the
hoses), the pump should immediately be brought to a stop, emptying and depressurizing the delivery hos
while taking all due the safety precautions (gloves, goggles, overalls, etc.).
1.5 - TOXIC AND/OR DANGEROUS LIQUID DOSAGE
To avoid risk from contact with hazardous liquids or toxic fumes, always adhere to the notes in this
instruction manual:
• Follow the instructions of the dosing liquid manufacturer
• Check the hydraulic part of the pump and use it only if it is in perfect condition
• Use only the correct materials fir the tubing, valves and seals to suit the liquid to be dosed : where
possible shield the tubing with PVC conduit.
• Before disconnecting the metering pump, make sure to flush out and neutralize the pump head with the
proper reagent liquid.
1.6 - ASSEMBLING AND DISMANTLING THE PUMP
1.6.1 -ASSEMBLY
See paragraph 3.0 “Installation and recommendation”
1.6.2 - DISMANTLEMENT
Proceed as follows when you dismantle the pump or before performing any operation on it:
1) Disconnect the plug from the mains.
2) See paragraph 1.2 shipping and transporting
Содержание POOLeasy pH
Страница 1: ...INSTRUCTIONS AND USER MANUAL POOLeasy pH POOLeasy Rx Power at the service of water...
Страница 14: ...11 STEP 5 Place the probe holder B by inserting the injection tube in the direction of the waterflow 1 2 3 Q...
Страница 15: ...12 STEP 6 Securization on the pipe 1 50 pipe 2 63 pipe K C L K C L O...
Страница 16: ...13 Vertical...
Страница 20: ...17 STEP 10 Installation of the short probe 80mm G J 1 2 3...
Страница 29: ...26 7 3 2 Installation of a long probe 120mm J G P 1 2 3...