R32
Split Type - Air Source Heat Pump 20220105
40
ACHP-H14/5R3HA-O / ACSHC-H48A5/ASR2DI 14kW capacity tables
Maximum
Outdoor
air temp.
LWT()
5 10 15 20 25
CC PI EER CC PI EER CC PI EER CC PI EER CC PI EER
-5
/ / / / / /
10.57
1.38
7.66
11.47
1.53
7.50
12.57
1.48
8.49
0
/ / / / / /
10.36
1.74
5.95
11.96
1.65
7.25
13.06
1.66
7.87
5
/ / / / / /
10.16
1.84
5.52
12.59
1.69
7.45
13.59
1.76
7.72
10
/ / / / / /
11.88
2.25
5.28
13.68
1.99
6.87
14.78
2.01
7.35
15
/
/
/ 11.58 2.41 4.80 13.68 2.41 5.68 16.08 2.41 6.67
16.98 2.41 7.05
20
8.73 2.25 3.88 13.36 3.24 4.12 15.46 3.41 4.53 16.46 3.22 5.11
17.06 2.92 5.84
25
11.17 3.24 3.45
15.07 3.89 3.87 17.17 4.21 4.08 17.57 4.06 4.33
17.67 3.49 5.06
30
11.08 4.02 2.76
14.68 4.59 3.20 16.48 4.62 3.57 16.78 4.24 3.96
16.68 3.8 4.39
35
10.99 4.93 2.23
14.29 5.44 2.63 15.89 5 3.18 15.89 4.56 3.48
15.89 4.24 3.75
40
8.69 4.65 1.87
10.45 4.45 2.35 11.28 4.04 2.79 12.78 4.17 3.06
13.78 3.89 3.54
43
5.77 3.83 1.51
6.68 3.37 1.98 7.9 3.13 2.52 9.1 3.3 2.76
11.27 3.37 3.34
Normal
Outdoor
air temp.
LWT()
5 10 15 20 25
CC PI EER CC PI EER CC PI EER CC PI EER CC PI EER
-5
/ / / / / /
8.64
1
8.64
9.45
1.09
8.67
10.29
1.07
9.62
0
/ / / / / /
8.46
1.25
6.77
9.89
1.18
8.38
10.76
1.18
9.12
5
/ / / / / /
8.26
1.37
6.03
10.2
1.24
8.23
11.19
1.32
8.48
10
/ / / / / / 9.7
1.67
5.81
11.18
1.45
7.71
12.08
1.5
8.05
15
/
/
/ 8.82 1.76 5.01 11.58 1.94 5.97 13.98 1.88 7.44
14.38 1.77 8.12
20
6.93 1.69 4.10
10.86 2.43 4.47 12.96 2.6 4.98 14.26 2.52 5.66
14.96 2.27 6.59
25
8.97 2.44 3.68
12.47 2.94 4.24 14.67 3.28 4.47 15.37 3.19 4.82
15.67 2.7 5.80
30
9.02 3.05 2.96
12.38 3.55 3.49 14.28 3.63 3.93 14.88 3.43 4.34
14.98 3.03 4.94
35
8.66 3.68 2.35
11.89 4.12 2.89 13.19 3.77 3.50 13.99 3.64 3.84
14.49 3.47 4.18
40
7.2 3.57 2.02
8.93 3.47 2.57 9.86 3.21 3.07 11.48 3.36 3.42
12.58 3.09 4.07
43
4.84 3.04 1.59
5.37 2.55 2.11 6.4 2.34 2.74 7.87 2.58 3.05
9.01 2.41 3.74
Minimum
Outdoor
air temp.
LWT
5 10 15 20 25
CC PI EER CC PI EER CC PI EER CC PI EER CC PI EER
-5
/ / / / / /
5.79
0.65
8.91
6.3
0.71
8.87
6.87
0.69
9.96
0
/ / / / / /
5.69
0.8
7.11
6.6
0.76
8.68
7.17
0.77
9.31
5
/ / / / / /
4.71
0.73
6.45
5.8
0.67
8.66
6.27
0.7
8.96
10
/ / / / / /
5.64
0.89
6.34
6.49
0.79
8.22
6.98
0.8
8.73
15
/
/
/ 5.63 1.05 5.36 6.46 1.02 6.33 7.26 0.9 8.07
8.44 0.96 8.79
20
3.78 0.86 4.40
5.08 1.07 4.75 6.72 1.26 5.33 8.11 1.36 5.96
8.72 1.26 6.92
25
4.6 1.17 3.93
5.5 1.19 4.62 7.22 1.5 4.81 8.39 1.63 5.15
8.76 1.43 6.13
30
4.59 1.45 3.17
5.4 1.43 3.78 6.99 1.66 4.21 8.05 1.73 4.65
8.35 1.6 5.22
35
4.26 1.7 2.51
5.82 1.9 3.06 6.88 1.82 3.78 7.72 1.85 4.17
8.25 1.85 4.46
40
3.57 1.68 2.13
4.49 1.65 2.72 5.13 1.58 3.25 6.43 1.79 3.59
7.41 1.78 4.16
43
2.03 1.09 1.86
2.87 1.24 2.31 3.62 1.23 2.94 4.29 1.33 3.23
5.95 1.53 3.89
Содержание ACHP-H04/4R3HA
Страница 23: ...R32 Split Air to Water Heat Pump 20220105 23 2 Hydronic Box AHM P24R2 C9D3A AHM P36R25 C9D9A AHM P60R25 C9D9A ...
Страница 43: ...R32 Split Type Air Source Heat Pump 20220105 43 ...
Страница 94: ...R32 Split Type Air Source Heat Pump 20220105 94 ...
Страница 97: ...R32 Split Type Air Source Heat Pump 20220105 97 Interface Interface setting Loading interface ...