R32
Split Type - Air Source Heat Pump 20220105
36
ACHP-H06/4R3HA-O 6kW capacity tables
Maximum
Outdoor
air temp.
LWT()
5 10 15 20 25
CC PI EER CC PI EER CC PI EER CC PI EER CC PI EER
-5
/ / / / / /
5.67
0.62
9.15
6.78
0.58
11.69
7.17
0.67
10.70
0
/ / / / / /
5.47
0.74
7.39
6.58
0.71
9.27
6.97
0.79
8.82
5
/ / / / / /
4.98
0.85
5.86
6.09
0.82
7.43
6.78
0.8
8.48
10
/ / / / / /
6.73
1.17
5.75
7.31
1.05
6.96
8.25
0.99
8.33
15
/
/
/ 6.32 1.16 5.45 8.52 1.52 5.61 8.57 1.32 6.49
9.28 1.13 8.21
20
5.83 1.44 4.05
7.05 1.49 4.73 8.58 1.55 5.54 8.75 1.36 6.43
9.4 1.16 8.10
25
7.56 1.87 4.04
7.77 1.84 4.22 8.63 1.6 5.39 8.92 1.4 6.37
9.52 1.22 7.80
30
6.94 1.92 3.61
7.73 1.97 3.92 8.21 1.72 4.77 8.63 1.53 5.64
9.21 1.37 6.72
35
6.27 1.96 3.20
7.65 2.09 3.66 7.74 1.82 4.25 8.3 1.64 5.06
8.86 1.5 5.91
40
4.22 1.56 2.71
5.5 1.86 2.96 6.33 1.78 3.56 7.05 1.73 4.08
8.3 1.69 4.91
43
3 1.23 2.44
4.22 1.6 2.64 5.5 1.64 3.35 6.3 1.65 3.82
7.97 1.67 4.77
Normal
Outdoor
air temp.
LWT()
5 10 15 20 25
CC PI EER CC PI EER CC PI EER CC PI EER CC PI EER
-5
/ / / / / /
4.64
0.45
10.31
5.59
0.41
13.63
5.9
0.45
13.11
0
/ / / / / /
4.49
0.53
8.47
5.44
0.49
11.10
5.75
0.53
10.85
5
/ / / / / /
4.07
0.64
6.36
4.97
0.59
8.42
5.64
0.59
9.56
10
/ / / / / /
5.49
0.86
6.38
5.96
0.75
7.95
6.47
0.69
9.38
15
/
/
/ 4.85 0.84 5.77 7.22 1.21 5.97 7.43 1.05 7.08
7.87 0.86 9.15
20
4.64 1.08 4.30
5.78 1.14 5.07 7.22 1.22 5.92 7.59 1.09 6.96
8.24 0.93 8.86
25
6.07 1.42 4.27
6.45 1.42 4.54 7.36 1.28 5.75 7.84 1.14 6.88
8.45 0.98 8.62
30
5.67 1.47 3.86
6.52 1.55 4.21 7.11 1.39 5.12 7.69 1.27 6.06
8.29 1.13 7.34
35
4.97 1.47 3.38
6.36 1.61 3.95 6.45 1.41 4.57 7.3 1.34 5.45
8.12 1.26 6.44
40
3.52 1.2 2.93
4.72 1.47 3.21 5.57 1.45 3.84 6.37 1.42 4.49
7.57 1.37 5.53
43
2.54 0.99 2.57
3.41 1.23 2.77 4.46 1.26 3.54 5.46 1.33 4.11
6.39 1.23 5.20
Minimum
Outdoor
air temp.
LWT
5 10 15 20 25
CC PI EER CC PI EER CC PI EER CC PI EER CC PI EER
-5
/ / / / / /
3.15
0.28
11.25
3.75
0.26
14.42
3.97
0.3
13.23
0
/ / / / / /
3.06
0.34
9.00
3.67
0.33
11.12
3.89
0.36
10.81
5
/ / / / / /
2.69
0.34
7.91
2.89
0.33
8.76
3.07
0.3
10.23
10
/ / / / / /
3.22
0.45
7.16
3.51
0.41
8.56
3.77
0.37
10.19
15
/
/
/ 3.14 0.51 6.16 4.07 0.64 6.36 3.93 0.51 7.71
4.68 0.47 9.96
20
2.55 0.56 4.55
2.77 0.51 5.43 3.8 0.6 6.33 4.37 0.6 7.28
4.86 0.53 9.17
25
3.12 0.7 4.46
2.9 0.6 4.83 3.69 0.61 6.05 4.32 0.6 7.20
4.78 0.54 8.85
30
2.92 0.72 4.06
2.93 0.65 4.51 3.56 0.66 5.39 4.23 0.66 6.41
4.67 0.62 7.53
35
2.5 0.68 3.68
3.18 0.75 4.24 3.44 0.69 4.99 4.09 0.69 5.93
4.66 0.68 6.85
40
1.82 0.57 3.19
2.43 0.69 3.52 2.94 0.71 4.14 3.6 0.76 4.74
4.49 0.79 5.68
43
1.15 0.39 2.95
1.85 0.61 3.03 2.53 0.67 3.78 2.99 0.7 4.27
4.22 0.79 5.34
Содержание ACHP-H04/4R3HA
Страница 23: ...R32 Split Air to Water Heat Pump 20220105 23 2 Hydronic Box AHM P24R2 C9D3A AHM P36R25 C9D9A AHM P60R25 C9D9A ...
Страница 43: ...R32 Split Type Air Source Heat Pump 20220105 43 ...
Страница 94: ...R32 Split Type Air Source Heat Pump 20220105 94 ...
Страница 97: ...R32 Split Type Air Source Heat Pump 20220105 97 Interface Interface setting Loading interface ...