R32
Split Type - Air Source Heat Pump 20220105
38
ACHP-H10/4R3HA-O 10kW capacity tables
Maximum
Outdoor
air temp.
LWT()
5 10 15 20 25
CC PI EER
CC PI EER CC PI EER CC PI EER CC PI EER
-5
/ / / / / /
7.31
0.73
10.01
9.27
0.86
10.78
9.83
0.81
12.14
0
/ / / / / /
7.06
0.81
8.72
8.21
0.85
9.66
8.75
0.8
10.94
5
/ / / / / /
7.25
0.91
7.97
7.61
0.81
9.40
8.12
0.77
10.55
10
/ / / / / /
6.91
0.83
8.33
8.53
0.88
9.69
9.16
0.94
9.74
15
/
/
/ 6.76 1.13 5.98 8.07 1.09 7.35 9.94 1.19 8.35
11.1 1.26 8.81
20
6.65 1.34 4.96
7.64 1.45 5.27 9.12 1.51 5.97 11.24 1.7 6.61
12.94 1.74 7.44
25
7.6 1.72 4.42
8.73 1.85 4.72 10.34 1.92 5.24 12.47 2.11 5.91
14.4 2.21 6.52
30
8.52
2.2
3.87
9.8
2.34
4.19
11.54
2.43
4.62
13.67
2.61
5.24 15.83
2.82
5.61
35
8.58 2.52 3.40
9.93 2.47 4.02 11.48 2.66 4.21 13.15 2.72 4.83
14.96 2.91 5.14
40
7.09 2.57 2.76
7.9 2.42 3.26 9.36 2.58 3.51 10.71 2.56 4.18
12.75 2.88 4.43
43
5.57 2.35 2.37
6.12 2.26 2.71 7.21 2.2 3.16 8.63 2.24 3.85
10.52 2.56 4.11
Normal
Outdoor
air temp.
LWT()
5 10 15 20 25
CC PI EER
CC PI EER CC PI EER CC PI EER CC PI EER
-5
/ / / / / /
5.96
0.53
11.25
7.61
0.62
12.27
8.05
0.59
13.64
0
/ / / / / /
5.97
0.58
10.29
6.77
0.61
11.10
7.19
0.57
12.61
5
/ / / / / /
5.78
0.67
8.63
6.08
0.59
10.31
6.55
0.58
11.29
10
/ / / / / /
5.62
0.63
8.92
6.94
0.66
10.52
7.52
0.72
10.44
15
/
/
/ 5.19 0.82 6.33 6.85 0.88 7.78 8.61 0.95 9.06
9.4 0.98 9.59
20
5.28 1.01 5.23
6.27 1.11 5.65 7.68 1.19 6.45 9.74 1.37 7.11
11.32 1.38 8.20
25
6.12
1.3
4.71 7.25
1.42
5.11
8.82
1.54
5.73
10.94
1.7
6.44 12.77
1.75
7.30
30
6.94 1.67 4.16
8.24 1.83 4.50 9.97 1.95 5.11 12.15 2.15 5.65
14.22 2.29 6.21
35
6.76 1.97 3.43
8.23 1.98 4.16 9.54 2.05 4.65 11.53 2.22 5.19
13.68 2.43 5.63
40
5.88 1.98 2.97
6.75 1.92 3.52 8.21 2.1 3.91 9.66 2.12 4.56
11.62 2.34 4.97
43
4.66 1.87 2.49
4.92 1.73 2.84 5.84 1.68 3.48 7.46 1.79 4.17
8.42 1.87 4.50
Minimum
Outdoor
air temp.
LWT
5 10 15 20 25
CC PI EER
CC PI EER CC PI EER CC PI EER CC PI EER
-5
/ / / / / /
4.02
0.34
11.82
5.07
0.4
12.68
5.39
0.38
14.18
0
/ / / / / / 3.9
0.38
10.26
4.53
0.39
11.62
4.83
0.37
13.05
5
/ / / / / /
3.42
0.35
9.77
3.6
0.31
11.61
3.84
0.3
12.80
10
/ / / / / /
3.28
0.36
9.11
4.03
0.38
10.61
4.33
0.41
10.56
15
/
/
/ 3.36 0.5 6.72 3.88 0.47 8.26 4.54 0.46 9.87
5.57 0.53 10.51
20
2.89 0.52 5.56
3 0.5 6.00 4.04 0.59 6.85 5.56 0.74 7.51
6.62 0.77 8.60
25
3.18 0.63 5.05
3.28 0.59 5.56 4.42 0.71 6.23 5.99 0.87 6.89
7.16 0.93 7.70
30
3.54 0.79 4.48
3.65 0.73 5.00 4.91 0.89 5.52 6.56 1.08 6.07
7.87 1.21 6.50
35
3.33 0.89 3.74
4.06 0.89 4.56 5 0.98 5.10 6.35 1.11 5.72
7.73 1.27 6.09
40
2.92 0.93 3.14
3.42 0.9 3.80 4.27 1.03 4.15 5.39 1.12 4.81
6.82 1.34 5.09
43
1.91 0.67 2.85
2.6 0.84 3.10 3.28 0.88 3.73 4.03 0.92 4.38
5.54 1.18 4.69
Содержание ACHP-H04/4R3HA
Страница 23: ...R32 Split Air to Water Heat Pump 20220105 23 2 Hydronic Box AHM P24R2 C9D3A AHM P36R25 C9D9A AHM P60R25 C9D9A ...
Страница 43: ...R32 Split Type Air Source Heat Pump 20220105 43 ...
Страница 94: ...R32 Split Type Air Source Heat Pump 20220105 94 ...
Страница 97: ...R32 Split Type Air Source Heat Pump 20220105 97 Interface Interface setting Loading interface ...