R32
Split - Air to Water Heat Pump 20220105
19
3.7 Space Heating, Space Cooling and Domestic Hot Water Compatible with Solar Water Heater
Floor heating loops & Heating Radiator &fan coil units are used for space heating, and fan coil units are
used for space cooling. The temperature in the domestic hot water tank is controlled by the hydronic box. A
temperature sensor needs to be placed in the domestic hot water tank and connected to the hydronic box.
When it is detected that the temperature of the domestic hot water tank is lower than the set temperature and
meets the requirements for solar hot water activation When conditions are met, turn on the solar water pump
to realize the solar hot water function.
Figure 3.7 Space heating, space cooling and domestic hot water compatible with solar water heater
REMARK
1 Outdoor
unit
14 Water
collector
2
Hydronic box
15
Bypass valve
3
Plate heat exchanger
16
Electric heating
4
Backup electric heater(optional)
17
Domestic hot water tank
5
Internal circulator pump
18
Coil 1 in the water tank
6
Wired controller
19
Coil 2 in the water tank
7
Stop valve
20
solar water pump
8
Motorized 3way valve
21
Solar panel
9
Balance water tank
RDT
Heating Radiator
10
External circulation pump
FLH
Floor heating loops
11
Twoway valve
FCU
Fan coil units
12
Mixing valve and mixing water pump
RT
Room thermostats
13 Distributor
Содержание ACHP-H04/4R3HA
Страница 23: ...R32 Split Air to Water Heat Pump 20220105 23 2 Hydronic Box AHM P24R2 C9D3A AHM P36R25 C9D9A AHM P60R25 C9D9A ...
Страница 43: ...R32 Split Type Air Source Heat Pump 20220105 43 ...
Страница 94: ...R32 Split Type Air Source Heat Pump 20220105 94 ...
Страница 97: ...R32 Split Type Air Source Heat Pump 20220105 97 Interface Interface setting Loading interface ...