background image

INTRODUCTION

AT-8070-D

 control board is suitable for two 230VAC actuators for single or double swinging gate.

The max absorption of the device is 650 W per  230Vac 50Hz. 
The setup of the parameters must be carried out after the installation of all the equipment.

ATTENTION

The Product must be installed by qualified personnel who can carry out the installation operation strictly in 
compliance with safety rules. The device must not be used incorrectly or for any purposes other than the 
ones designed for. Before proceeding with the installation it is necessary to read the instruction manual 
carefully in order to avoid danger to either the users or the equipment. It is necessary to power the device 
using a 6A bipolar thermomagnetic switch equipped with a differential with an operating current of 0.03 A. 
Before currying out any installation or maintenance operations turn off the power supply to the device with 
the bipolar switch. The equipment must not be tampered with or modified in any way. it is necessary to turn off 
the power supply to the equipment before installing it or opening the enclosure.

The manufacturer reserves the right to make changes to the product without  prior notice. Therefore 
this manual may not correspond exactly to the product specifications.

 AT-8070-D Control Board for swinging gates

 

DESCRIPTION

P1A

 

  =  Operating time programming button

P2B

 

  =  Remote control programming button

DSW1

  =  Micro Switches

TR1, TR2, TR3

 =  Adjustable trimmers

RESET

  = Reset Button

F2

 

  =  Low Voltage Fuse

TF1

  =  Transformer

CN1

  =  Receiver

M1

  =  Low Voltage Input Terminal

F1

  =  230Vac Fuse

M2

 

  =  230Vac Input Terminal

K1 – K3

 

  =  Relay

2

Ÿ

Ÿ

EN60950

Ÿ

EN301489-1

Ÿ

EN301489-3

Ÿ

EN300220-3

Radio & Telecommunications Terminal Equipment directive 1999/5/EC 

AUTOTECH - G .KAPSALIS
8, Archimidous str. 12134 Peristeri Athens, 
Greece, Tel: +302105780019, Fax: +302105785112

In accordance with the following directives:

DECLARATION OF CONFORMITY

hereby declare that:
       

Product : AT8070 Remote Control Board for Opening Doors

       Model : AT-8070-D

is in conformity with the applicable 
requirements of the following documents.

I hereby declare that the equipment named above has been designed to 
comply with the relevant sections of the above referenced specifications. 
The unit complies with all the applicable essential requirements of the 
directives mentioned.

Name:

Apergis Antonios

Position: Technical Director

Peristeri, 28 November 2013

F2

TR1

TR2

TR3

P1A

P2B

CN1

M1

F1

M2

K1

K2

K3

TF1

RESET

Содержание AT-8070-D

Страница 1: ...INSTALLATION AND PROGRAMMING MANUAL FOR AT 8070 D CONTROL BOARD FOR 230 Vac SWINGING GATES MOTOR ...

Страница 2: ... to make changes to the product without prior notice Therefore thismanualmaynotcorrespondexactlytotheproductspecifications AT 8070 D Control Board for swinging gates DESCRIPTION P1A Operating time programming button P2B Remote control programming button DSW1 Micro Switches TR1 TR2 TR3 Adjustable trimmers RESET Reset Button F2 Low Voltage Fuse TF1 Transformer CN1 Receiver M1 Low Voltage Input Termi...

Страница 3: ...osing and you press START button the door opens if the door is opening START command stops the door During auto close START command closes the door If you press START after STOP command the door closes AUTOMATIC If the door is closed or closing and you press START button the door opens START command is ignored while the door is open During auto close START command closes the door If you press STAR...

Страница 4: ... LED and the FLASHING LIGHT must turn ON ant then OFF simultaneously For rolling coded remote controls repeat procedure for each control For Fixed coded remotecontrolsjustcopytheremotecontrols Remotecontrolprogramminforpedestrian When the door is closed press until TEST LED starts blinking Do not relase TEST LED starts blinking faster RealeaseRADIO Within10seconds pressthebuttonoftheremotecontroly...

Страница 5: ... failure at the first closing of the door the operation time will be greater approximately 12 seconds correctly PROGR speed has began SLOW M2 M 1 M2 M1 M 2 M1 M2 M1 M2 M1 M2 M1 M2 M1 M2 M1 M2 M1 M2 M1 M 2 M1 M2 M1 2 START 3 START 4 START 5 START 6 START 7 START 8 START 9 START 10 START 11 START 12 START 13 START M2 M1 1 START First START command initiates the operation time programming causing the...

Страница 6: ...ttings just completed ATTENTION After RESET or power supply failure at the first closing of the door the operation time will be greater approximately 12 seconds PROGR PROGR SLOW M2 M1 M2 M1 1 START 2 START M2 M1 2 START M2 M1 4 START M2 M1 5 START M2 M1 6 START M2 M1 7 START M 2 M1 8 START M2 M1 9 START First START command initiates the operation time programming causing the first motor to OPEN Th...

Страница 7: ...ust be issued when the door totally opens Fourth START command defines starting point for slow speed for the door while closing Fifth START command defines the end of the door operation time and must be issued when the door totally closes OPERATION TIME PROGRAMMING FOR SINGLE LEAFED SWINGING GATE WITHOUT SLOW SPEED at maximum needed to move the door correctly Totally close the door Press PROGR unt...

Страница 8: ... POWER SUPPLY BIPOLAR THERMOMAGNETIC SWITCH WITH DIFFERENTIAL 6A 30ma 8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 DL1 DL2 DL3 DL4 DL5 DL6 START STOP ΝΟ ΝΟ ΝC 24V 2W MAX ΝΟ ΝC COM NO COM NC NO COM NC 230VAC COM CLOSE OPEN C COM CLOSE OPEN ΝC TOTAL STOP C M1 M2 MOTOR 1 MOTOR 2 20 21 22 23 24 25 16 17 11 12 19 18 1 6 10 2 3 9 1 6 10 7 8 5 4 ...