INSTALLATION
2
1,5mm
Prior to the electric connection shut down the 230V 50Hz power supply and adjust motor torch to
minimun.
2
Use
0,5mm
to connect the buttons, photocells and 24V power supply. For connections with electric bolt
and lights use at least
cables. For 230V 50Hz connections and motor connections use at least
2
2.5mm
cables
.
Termina M1l
ANT
= Antenna
COM
= Input and Flashing light Common
START
= Input Button N.O. (Open / Close)
ST.PED
= Input Button N.O. (Pedestrian Open)
STOP
= Input Button N.C. (STOP)
SAFETY
= Safety Contact Input N.C.
COM
= Input and Flashing light Common
PHOTO-1
= External Photocell Command Input N.C.
PHOTO-2
= Internal Photocell Command Input N.C.
W. LΙGHT 2W 24V
= Flashing Light 24Vdc 2W max. Output
+24V
= +24Vdc Power Supply
-24V
= -24Vdc Power Supply
LOCK
= 12Vac Electric Lock Output
Terminal Μ2
PE
= Ground Input
L
= Line Input 230V 50Hz
N
= Neutral Input 230V 50Hz (Electric Light Common)
FLASH
= Electric Light 230V 50Hz 15 W max.
Motor 1 COM
= Motor 1 Common
Motor 1 C
= Motor 1 Close
Motor 1 O
= Motor 1 Open
Motor 2 COM
= Motor 2 Common
Motor 2 C
= Motor 2 Close
Motor 2 O
= Motor 2 Open
-
.
N.C.
-
- If one of the Ν.Ο. (START and S.TP) is closed, or one of the N.C.inputs is openthe TEST_LED blinks fast. In this case
track programming is not available.
It is very important to firmly tight the signal cables of terminal
Μ2
and power cables on terminal
M1
separately to avoid errors Use Jumpers to all
inputs when not in use.
Do not connect any kind of device in the terminal inputs other than the one they are designed for.
OPERATION MODES
CONDOMINIUM AUTOMATIC:
If the door is closed or closing and you press
START
button the door
opens
. If the door is
opening, START
command is
ignored, while during
auto close, START
command resets time. If you press
START
after
STOP
command the door
closes.
SUPERAUTOMATIC:
If the door is closed or closing and you press
START
button the door
opens.
if the door is
opening START
command
stops the door
.
During
auto close,
START
command closes the door. If you press
START
after
STOP
command the
door closes.
AUTOMATIC:
If the door is closed or closing and you press
START
button the door
opens.
START
command is ignored while the door
is
open.
During
auto close, START
command closes the door. If you press
START
after
STOP,
command the door
closes.
SEMIAUTOMATIC:
START
command controls opening, closing and stoping the door. When the door is open you must press
START
to
close the door .
Auto close
is disabled. If the door is opening and you press
START
the door stops and you must give a
second START command to close the door. If
START
is pressed during closing function, the door starts to open. If you
press
START
after a
STOP
command the door closes.
STEP BY STEP:
When the door is closed and you press
START,
the door opens. During opening if
START
is pressed, the door stops. if
you then press
START
the door closes and by pressing
START
again the door stops. if you press
START
after a
STOP
command
,
the door closes.
Choose operation mode with micro Switches 1,2,3 and 6, according to the following board “CHOOSE
OPERATION MODE” (after each change of operation mode you must short circuit jumper JR1 for a few seconds
to apply change).
(1)
Comfort operation
allows the door to close
5
seconds after the photocells command, independent of the AUTO
CLOSE programmed time.
(2) P
hotocell retrigger
resets AUTO CLOSE time after any command from Photocells.
OFF
OFF
OFF
OFF
Condominium automatic
OFF
OFF
ON
OFF
Condominium aut comfort (1)
OFF
ON
OFF
OFF
Superautomatic
OFF
ON
ON
OFF
Superaut comfort (1)
ON
ON
OFF
OFF
Automatic
ON
ON
ON
OFF
Aut comfort (1)
ON
OFF
OFF
OFF
Semiautomatic
ON
OFF
ON
OFF
Step by Step
OFF
OFF
OFF
ON
Condominium aut photocell retrigger (2)
OFF
ON
OFF
ON
Superaut photocell retrigger (2)
ON
ON
OFF
ON
Aut photocell retrigger (2)
CHOOSE OPERATION MODE
Dip 1 Dip 2 Dip 3 Dip 6 OPERATION
3