background image

INSTALLATION

2

 

1,5mm

Prior to the electric connection shut down the  230V 50Hz power supply and adjust motor torch to 
minimun.

2

Use 

0,5mm  

to connect the buttons, photocells and  24V power supply. For connections with electric bolt 

and lights  use at least 

  cables. For 230V 50Hz connections and motor connections use at least  

2  

2.5mm

cables

.

 

Termina M1l

ANT

= Antenna

COM

 

=  Input and Flashing light Common 

START 

                 =  Input Button N.O. (Open / Close)

ST.PED 

=  Input Button N.O. (Pedestrian Open)

STOP 

=  Input Button N.C. (STOP)

SAFETY  

                   =  Safety Contact Input N.C.

COM

 

=  Input and Flashing light Common

PHOTO-1

                   =  External Photocell Command Input N.C.

PHOTO-2

                   =  Internal Photocell Command Input N.C. 

W. LΙGHT 2W 24V

     =  Flashing Light  24Vdc 2W max. Output 

+24V 

=  +24Vdc Power Supply 

-24V 

=  -24Vdc Power Supply

LOCK 

=  12Vac Electric Lock Output

Terminal Μ2

PE

=  Ground Input

=  Line Input 230V 50Hz

=  Neutral Input 230V 50Hz (Electric Light Common)

FLASH 

                 =  Electric Light 230V 50Hz 15 W max.

Motor 1 COM 

=  Motor 1 Common

Motor 1 C 

= Motor 1 Close

Motor 1 O 

=  Motor 1 Open

Motor 2 COM

=  Motor 2 Common

Motor 2 C

 

=  Motor 2 Close

Motor 2 O 

=  Motor 2 Open

 N.C. 

- If one of the Ν.Ο. (START and S.TP) is closed, or one of the N.C.inputs is openthe  TEST_LED blinks fast. In this case 
track programming is not available.

It is very important to firmly tight the signal cables of terminal 

Μ2

and power cables on terminal 

M1

 separately to avoid errors Use Jumpers to all

inputs when not in use.

 

Do not connect any kind of device in the terminal inputs other than the one they are designed for.

OPERATION MODES

CONDOMINIUM AUTOMATIC:  

If the door is closed or closing and you press 

START 

button the door 

opens

. If the door is 

opening, START

 command is 

ignored, while during 

auto close, START

 command resets time. If you press 

START

 after 

STOP 

command the door 

closes.

SUPERAUTOMATIC:

If the door is closed or closing and you press 

START 

button the door 

opens. 

if the door is 

opening START 

command 

stops the door

.

 During 

auto close,

 

START 

command closes the door. If you press 

START 

after 

STOP 

command the 

door closes.

AUTOMATIC:

If the door is closed or closing and you press 

START 

button the door 

opens.

 

START 

command is ignored while the door 

is 

open.

During 

auto close, START 

command closes the door. If you press  

START 

after 

STOP, 

command the door 

closes.

SEMIAUTOMATIC:

 

START

 command controls opening, closing and stoping the door. When the door is open you must press 

START 

to 

close the door .

Auto close

 is disabled. If the door is opening and you press 

START 

the door stops and you must give a 

second START command to close the door. If 

START 

is pressed during closing function,  the door starts to open. If you 

press 

START 

after a 

STOP 

command the door closes.

STEP BY STEP:

When the door is closed and you press 

START, 

the door opens. During opening if  

START 

is pressed, the door stops. if 

you then press 

START 

the door closes and by pressing 

START 

again the door stops. if you press 

START 

after a 

STOP 

command

the door closes.

Choose operation mode with micro Switches  1,2,3 and 6, according to the following board “CHOOSE 
OPERATION MODE”  (after each change of operation mode you must short circuit jumper JR1 for a few seconds 
to apply change).

(1) 

 Comfort operation 

allows the door to close 

5

 seconds after the photocells command, independent of the AUTO 

CLOSE programmed time.
(2) P

hotocell retrigger 

resets AUTO CLOSE time after any command from Photocells.

OFF 

OFF 

OFF 

OFF 

Condominium automatic

OFF 

OFF 

ON 

OFF 

Condominium aut comfort (1)

OFF 

ON 

OFF 

OFF 

Superautomatic

OFF 

ON 

ON 

OFF 

Superaut comfort (1)

ON 

ON 

OFF 

OFF 

Automatic

ON 

ON 

ON 

OFF 

Aut comfort (1)

ON 

OFF 

OFF 

OFF 

Semiautomatic

ON 

OFF 

ON 

OFF 

Step by Step

OFF 

OFF 

OFF 

ON 

Condominium aut photocell retrigger (2)

OFF 

ON 

OFF 

ON 

Superaut photocell retrigger (2)

ON 

ON 

OFF 

ON 

Aut photocell retrigger (2)

CHOOSE OPERATION MODE

Dip 1   Dip 2    Dip 3   Dip 6    OPERATION

3

Содержание AT-8070-D

Страница 1: ...INSTALLATION AND PROGRAMMING MANUAL FOR AT 8070 D CONTROL BOARD FOR 230 Vac SWINGING GATES MOTOR ...

Страница 2: ... to make changes to the product without prior notice Therefore thismanualmaynotcorrespondexactlytotheproductspecifications AT 8070 D Control Board for swinging gates DESCRIPTION P1A Operating time programming button P2B Remote control programming button DSW1 Micro Switches TR1 TR2 TR3 Adjustable trimmers RESET Reset Button F2 Low Voltage Fuse TF1 Transformer CN1 Receiver M1 Low Voltage Input Termi...

Страница 3: ...osing and you press START button the door opens if the door is opening START command stops the door During auto close START command closes the door If you press START after STOP command the door closes AUTOMATIC If the door is closed or closing and you press START button the door opens START command is ignored while the door is open During auto close START command closes the door If you press STAR...

Страница 4: ... LED and the FLASHING LIGHT must turn ON ant then OFF simultaneously For rolling coded remote controls repeat procedure for each control For Fixed coded remotecontrolsjustcopytheremotecontrols Remotecontrolprogramminforpedestrian When the door is closed press until TEST LED starts blinking Do not relase TEST LED starts blinking faster RealeaseRADIO Within10seconds pressthebuttonoftheremotecontroly...

Страница 5: ... failure at the first closing of the door the operation time will be greater approximately 12 seconds correctly PROGR speed has began SLOW M2 M 1 M2 M1 M 2 M1 M2 M1 M2 M1 M2 M1 M2 M1 M2 M1 M2 M1 M2 M1 M 2 M1 M2 M1 2 START 3 START 4 START 5 START 6 START 7 START 8 START 9 START 10 START 11 START 12 START 13 START M2 M1 1 START First START command initiates the operation time programming causing the...

Страница 6: ...ttings just completed ATTENTION After RESET or power supply failure at the first closing of the door the operation time will be greater approximately 12 seconds PROGR PROGR SLOW M2 M1 M2 M1 1 START 2 START M2 M1 2 START M2 M1 4 START M2 M1 5 START M2 M1 6 START M2 M1 7 START M 2 M1 8 START M2 M1 9 START First START command initiates the operation time programming causing the first motor to OPEN Th...

Страница 7: ...ust be issued when the door totally opens Fourth START command defines starting point for slow speed for the door while closing Fifth START command defines the end of the door operation time and must be issued when the door totally closes OPERATION TIME PROGRAMMING FOR SINGLE LEAFED SWINGING GATE WITHOUT SLOW SPEED at maximum needed to move the door correctly Totally close the door Press PROGR unt...

Страница 8: ... POWER SUPPLY BIPOLAR THERMOMAGNETIC SWITCH WITH DIFFERENTIAL 6A 30ma 8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 DL1 DL2 DL3 DL4 DL5 DL6 START STOP ΝΟ ΝΟ ΝC 24V 2W MAX ΝΟ ΝC COM NO COM NC NO COM NC 230VAC COM CLOSE OPEN C COM CLOSE OPEN ΝC TOTAL STOP C M1 M2 MOTOR 1 MOTOR 2 20 21 22 23 24 25 16 17 11 12 19 18 1 6 10 2 3 9 1 6 10 7 8 5 4 ...

Отзывы: