background image

Autoplugin RCP-F2

Version 7.3

Technical Description

User Manual

Rev. A

Содержание RCP-F2

Страница 1: ...Autoplugin RCP F2 Version 7 3 Technical Description User Manual Rev A...

Страница 2: ...ter control by various impulses Heater status signals outputs Embedded remote control of the heater by using the original 3 button Ford car s key Remote cancellation of heater startup programmed in th...

Страница 3: ...e impulse If the heater is idle positive impulse on this input cancels the program start of the heater programmed by DIS Table 1 X1 pin number Signal Name Polarity Wire colour 1 Heater_off White 2 Hea...

Страница 4: ...by the leading edge of the impulse This input is suitable for the most alarm systems and GSM modules connections in order to control the heater remotely X1 5 Button The input for multi functional but...

Страница 5: ...The output can be used to control an external device by time of heater operation Time of signal appearing is defined by the setting 5 1 When the heater operates for programmed time the impulse of nega...

Страница 6: ...nted You can see series of double flashes in direction indicators of rear view mirrors when the heater starts to operate choose setting 6 1 2 to activate this function 3 The RCP adjusted by default on...

Страница 7: ...isabling by RCP settings or in case of one time disabling by the button pressing On Running Off Boost extension On Running On This function lets the heater keep working after the engine has been switc...

Страница 8: ...rresponds to a digit The LED and the direction indicators symbols in the DIS confirm each button press the LED briefly goes off the left direction indicator flashes one time when the first or the thir...

Страница 9: ...lsius degrees 1 2 1 Not applied 1 2 2 Higher than 0 degrees 1 2 3 Higher than 10 degrees 1 2 4 Higher than 20 degrees 1 2 5 Higher than 30 degrees 1 2 6 Higher than 40 degrees 1 2 7 Higher than 50 deg...

Страница 10: ...Lock button s function for the heater remote control 3 3 1 Heater start only 3 3 2 Start of idle heater stop of operated heater 3 4 Lock button presses count to activate the RCP module 3 4 1 Heater co...

Страница 11: ...n of successful startup of the heater from remote control 6 1 1 Off 6 1 2 Series of double flashes 6 2 Indication of unsuccessful startup of the heater from remote control 6 2 1 Off 6 2 2 Series of si...

Страница 12: ...Engine runs RPM impulses 7 5 6 Ventilation is on during the heater operation potential 7 5 7 Ventilation is off during the heater operation potential 7 5 8 Disable the output 8 Settings reset 8 1 1 Ap...

Страница 13: ...unadjusted condition after battery discharging or disconnection See chapter Preparation for Work to adjust the heater 2 No answer from the heater followed the start command The engine is hot no need t...

Страница 14: ...5 Unsuccessful start The heater was switched off spontaneously at startup Make diagnostics of the heater if the error occurs again 6 Operation cycle too short The heater was switched off spontaneousl...

Страница 15: ...RCP Remote Control Plug in electronic module for the heater remote control DIS Driver Information System of the instrument cluster BHM or Boost Heat Mode operational mode of the heater when it operate...

Страница 16: ...16 Autoplugin ES www autoplugin ru...