!!!Warning!!! Cell X Low Amps
Problem
Cell may be depleted.
Typical Solution
Check for visual wear on the edges of the terminal blades, which may be an indication that the
cell is depleted. Replace if depleted.
Problem
Low salt level.
Typical Solution
Verify salt level using a separate salinity tester (digital meter, salt strips, or reagent test kit).
Problem
The cell cord may be disconnected or damaged.
Typical Solution
Check the cell cord for tight connections on the cell and on the power supply. Tighten as
needed.
Check the plug for burns. Replace as needed.
Problem
The cell may be heavily scaled.
Typical Solution
Remove and acid wash. See "Servicing the Cell" on page 13.
If all steps above have been performed and the error message is still shown, do the
following:
1. Turn off power to the unit by the power switch on the control panel and wait three (3) minutes. If the unit
was in Boost mode, deactivate the Boost cycle prior to powering off the unit.
2. Power the unit on and put in Boost mode, or increase the purifier output to 100%, and let run for three
(3) minutes.
3. Press the TEST button and record the displayed diagnostics information. Be sure to make note of the
cell amps and volts for
each cell.
4. Deactivate Boost mode or return purifier output % to the original setting.
If test shows low volts and low amps, there may be a problem with the power module. Contact
your local AutoPilot
®
service center or AquaCal AutoPilot Customer Support for further
assistance.