SECTION 5 - FEATURES
l
Patented temperature compensation for chlorine output control
l
Programmable microprocessor control
l
Digitally controlled power to the cell
l
Tri-sensor circuitry to monitor water flow, water temperature, and salt level
l
Calculates and displays amount of salt needed to reach the recommended 3,000 ppm (mg/L) salt
concentration level
l
On board diagnostic and test programs
l
Interface for connection to an external ORP controller
5.1 Patented Temperature Compensation
WARNING
-
Failure
to
heed
the
following
may
result
in
permanent
injury
or
death.
l
Pool
or
Spa
water
temperature
should
not
exceed
104
°F
(40
°C).
The
water
temperature
sensor
works
in
conjunction
with
the
purifier
%
feature
to
automatically
adjust
chlorine
output
based
upon
changes
in
water
temperature.
This
feature
operates
between
55
°F
and
125
°F
(13
°C
-
52
°C).
As
water
temperature
falls
below
65
°F
(18
°C),
the
controller
will
reduce
the
maximum
output
%
that
can
be
selected.
This
feature
prevents
the
controller
from
generating
excessive
chlorine
in
cold
water
where
it
is
not
needed
and
prevents
premature
cell
failure.
At
55
°F
(13
°C)
or
colder
water
temperatures
the
controller
will
adjust
to
a
fixed
1%
output,
thus
preventing
over-chlorination
and
premature
cell
failure.
This feature is disabled when connected to an ORP controller and purifier output is set to 0%.
5.2 Water Manifold Assemblies - Available Options
5.2.a Automatic - Flow Bypass Manifold Assembly
The AutoPilot
®
manifold assembly is available with two (2), three (3), four (4), five (5), or six (6)
cells, including the Tri-sensor. Each cell must have a corresponding power module.
Example:
If
you
order
a
PPP-
4
unit,
there
will
be
four
(4)
power
modules
in
the
control
center
and
a
941-
415AC
manifold
assembly
with
four
(4)
cells
and
one
(1)
Tri-sensor
assembly.
The manifold is connected into the plumbing after all other equipment. Water from the pool / spa
is moved though the manifold by the circulation pump. Ensure there is enough flow to the
manifold base (min. 30 – 50 gpm / max. 70 gpm (min. 6.8 – 11.3 m³/hr / max. 22.6 m³/hr)).
The manifold uses four key components:
l
The
Tri-sensor
provides data (from electronic sensors) to the Pool Pilot
®
for monitoring water flow, water
temperature, and salt concentration level. The Pool Pilot
®
uses this data to determine if conditions are
suitable for the cell to operate; the signal read from the temperature sensor allows the automatic
temperature compensation feature to function.
l
The
Cell
(PPCx) receives power from the Pool Pilot
®
and converts the salt contained in the water to
chlorine.
l
The
Strainer Screen
prevents debris in the water from entering the Tri-sensor or cell and requires
periodic inspection and cleaning.
l
The
Bypass Check Valve
allows the water flow rate to be slowed and optimized through the cell while
permitting the pump to continue to circulate water to-and-from the pool / spa at full flow rates. The
reduced water flow through the cell results in a more efficient "Super-Chlorination” effect, resulting in
improved overall sanitization.