Page - 27
Once the Pool Pilot
®
is programmed to the pool water volume, the controller will automatically
indicate how much salt is required to attain salt level of 3,000 ppm (mg/L). For information on
amount of salt to be added relative to the volume of water to be treated vs. existing salt level,
refer to the "Reference" section in this manual. See "Salt Addition Chart" on page 40.
How to Add Salt to Pool
CAUTION - Failure to heed the following may result in equipment damage.
l
For newly plastered pools, do not use a pool cleaner or vacuum head with wheels as wheels can leave
track marks.
l
Do not allow granular salt to pile up in one location without brushing as staining may occur.
The circulation pump should be run continuously until the salt has been fully dissolved –
typically 24 hours. Add salt directly to pool or spa (if a spa-only installation) and over the main
drain (if main drain is present). If there is no main drain, a vacuum head may be used to
encourage salt circulation. Distributing the salt by brushing is also helpful; brush the salt toward
the main drain (if one is present). Set pump operation to normal run time after salt has fully
dissolved into water.
If the salt level becomes undesirably high, the only way to remove excess salt is to partially drain
the pool / spa and refill with fresh water.
8.7 Programming at Installation
The Pool Pilot
®
requires the pool volume be programmed into the installer menu. The Pool Pilot
®
will then indicate how many pounds (kg) of salt to add should salt levels fall.
1. Enter the “Installer menu” and program "Set pool volume" for specific pool. See "Calculating Pool
a. Press MENU/ENTER.
b. Press
△
or
▽
until “Installer menu” is displayed.
c. Press MENU/ENTER.
d. Press
△
or
▽
until “Set pool volume” is displayed, then press MENU/ENTER.
l
Factory setting is 000 gallons (000 liters).
l
The range is 000 to 1,000,000 gallons (000 to 4,000,000 liters).
e. Press
△
or
▽
until correct pool size (gallons or liters) is displayed; then press
MENU/ENTER.
f. “Exit menu mode” will be displayed. Press MENU/ENTER.
2. Configure the following as needed. See "Review of Main Menu Programming" on page 19.
l
Alarm (On / Off)
l
Set reverse time
l
Set cell power (High / Low)
l
English / Metric (gallons/liters, lbs/kg, ppm / mg/L)
l
Temperature units (°F or °C)
3. Press
△
or
▽
to adjust chlorine output to 50%.
Содержание Pool Pilot Professional PPP-2