Page - 15
Control Unit and Manifold Assembly
Figure 15
l
Turn off power to the control center at the circuit breaker. Turn off power to the main
filtration pump.
l
Drain all water from the manifold assembly (cell and Tri-sensor), pump, filter, supply
and return lines prior to freezing weather.
l
If desired, AutoPilot
®
plug kit #996 may be purchased to cover the openings. The
manifold assembly, including the cell, Tri-sensor and cables may be stored indoors.
l
The control unit is not affected by the cold and does not need to be removed.
6.5 Spring Start Up
It is recommended the water be manually chlorine-shocked when first starting up the pool in the
springtime. Test water and add the appropriate chemicals to balance the pool water per the
levels recommended in this manual. See "Water Balance and Chemistry Recommendations" on
page 4. Be sure to check salt and Cyanuric acid (stabilizer), bringing those readings up to the
recommended levels. It is also a good idea to inspect the cell, manifold screen, and test the Tri-
sensor flow switch; clean and/or replace those items as necessary. See "Removing / Inspecting /
Cleaning Tri-sensor" on page 11. See "Servicing the Cell" on page 13.
SECTION 7 - PROGRAMMING
7.1 Control Panel
7.1.a Button Overview
Control Panel
Figure 16
7.1.b On / Off Power Circuit Breaker
This main switch activates and deactivates the power going to the control center.
When an extreme power overcurrent occurs, the circuit breaker will trip to the off ("0") position.
To reactivate, turn completely off by making sure both sides of the switch are in the down
position. Turn the unit back on by flipping the switch up to the on ("1") position .
7.1.c Up or Down (
△
/
▽
) Buttons
Use the
△
or
▽
buttons to either increase or decrease the purifier output level. This is also
used in conjunction with the MENU/ENTER button to step through the menu selections.