Page - 19
After the optimal output percentage (%) has been determined, this setting will not normally
require further adjustment. Select a Boost cycle to compensate for increased bather usage or
heavy rainfalls (which can both quickly consume chlorine).
7.3 Review of Main Menu Programming
Once programmed for the installation site, the following menu items should not require regular
access. See "Basic Operational Programming" on page 17.
After completing a function, the next function in sequence will be displayed for selection. This
does not apply to those functions that exit service mode upon completion such as Force
Reverse and Calibrate Salt.
7.3.a Enable / Disable Audible Alarm
The alarm will sound when there is no flow or low salt. Entering TEST or MENU/ENTER will
temporarily silence the alarm. The alarm can be silenced by turning the power off or by selecting
"Alarm Disabled", but will sound again once power is restored.
Note: If alarm is due to low or no water flow, the alarm will automatically silence in 10 minutes.
Upon restoration of flow, normal Audio Alarm operation will resume.
1. Press MENU/ENTER, press
▽
until “Alarm on/off” is displayed, then press MENU/ENTER.
2. Press
△
or
▽
until "Alarm Enable" or "Alarm Disable” is displayed, then press MENU/ENTER to
select desired option. When complete, the unit will automatically advance to the next menu option.
7.3.b Boost
The Boost feature is used to increase the purifier % from its normal setting to 100% for a
cumulative amount of time between one (1) and seventy two (72) hour period of pool pump run
time. When the Boost period expires or is manually terminated, the purifier % returns to its
previous setting and normal operation.
1. From the normal operation mode, press the MENU/ENTER and use the
▽
arrow until Boost
appears.
2. Press the MENU/ENTER to enter the Boost menu.
3. Use the
△
or
▽
until the desired amount of time is shown and press MENU/ENTER to select the
value. When complete, the unit will automatically advance to the next menu option.
To cancel the Boost function:
1. From the normal operation mode, press the MENU/ENTER and use the
▽
arrow until Boost
appears.
2. Press the MENU/ENTER to enter the Boost menu.
3. Use the
▽
arrow until Off is shown. Press MENU/ENTER to save.
If an external time clock or controller turns off power to the chlorinator while Boost is active, the
Boost timer is stored in memory and the Boost time countdown will resume when power is
reapplied to the unit.
If water flow is stopped during a Boost cycle, chlorine generation will stop while there is no flow
but the Boost timer will continue to count down as long as the Pool Pilot
®
has power.