Page - 17
7.1.g Cell Indicator Lights
There are six (6) cell indicator lights on the control panel. The lights flash as the processor
communicates to each specific cell. They will show solid green when a cell is generating
chlorine. The light will not be illuminated if the cell is not generating chlorine at that time or if
there is not a corresponding cell to that position.
Note: Wherever there is no cell connected to the control center, the display will show “CELL X
not found”.
7.1.h Display Overview
The first line of the display typically indicates purifier (chlorine) output level in percentage (%), or
whether the system is in Boost mode with hours remaining.
The second line will show the following information:
l
The temperature in either °F or °C will be shown
l
“On” in the lower right corner will indicate whether the cell is generating chlorine
l
A small dot in the bottom right corner indicates the self-cleaning forward / reverse cycle
l
Salt level in ppm (mg/L)
7.2 Basic Operational Programming
7.2.a Adjusting the Purifier Output %
Typically, once the initial setting is established, very little adjustment is needed. The Purifier
output % setting refers to the amount of time the cell is energized within a fifteen (15) minute
cycle. The system cycles on-and-off as indicated on the display's lower right display and “On”
when generating chlorine. Higher settings will generate more chlorine.
1. Use the
△
or
▽
buttons to adjust the purifier (chlorine) output percentage to the desired output: from
0% (off) to 100 % ; then press MENU/ENTER to save the new output value and default back to the
normal display. At start up of a new system, the standard output setting starting point is 50%.
50%
setting
=
50%
of
15
minutes
or
7.5
minutes
ON
and
7.5
minutes
OFF
25% setting = 3.75 min ON, 11.25 min OFF
Once the percentage is set, the unit will implement the temperature compensation algorithm
based on current water temperature.
7.2.b Boost
The Boost feature is used to increase the purifier % from its normal setting to 100% for a
cumulative amount of time between one (1) and seventy two (72) hour period of pool pump run
time. When the Boost period expires or is manually terminated, the purifier % returns to its
previous setting and normal operation.
1. From the normal operation mode, press the MENU/ENTER and use the
▽
arrow until Boost
appears.
2. Press the MENU/ENTER to enter the Boost menu.
3. Use the
△
or
▽
until the desired amount of time is shown and press MENU/ENTER to select the
value. When complete, the unit will automatically advance to the next menu option.
To cancel the Boost function:
1. From the normal operation mode, press the MENU/ENTER and use the
▽
arrow until Boost
appears.
2. Press the MENU/ENTER to enter the Boost menu.
3. Use the
▽
arrow until Off is shown. Press MENU/ENTER to save.
Содержание Pool Pilot Professional PPP-2