3 Driving operation
26
© Copyright Reserved Autonics Co., Ltd.
3.1.4.3
Warning Display Function
Even though the warning occurs, the operation is still available and remains the torque.
If the warning source is removed, it automatically returns without the Alarm Reset.
The warning is displayed as Green on the front “PWR”LED, and able to monitro from the
atMotion or CC-Link communication.
The types of warning can be checked with alarm number on the 7 Segment and atMotion or
CC-Link communication.
When warning occurs, it can be checked through the CC-Link Remote I/O Warning [RXn5]
and the warning code is displayed below Remote Register [RWrn1].
If the limit waring occurs, it will not operate to the same direction as occurred limit and it
can be cleared by operating opposite direction from the occurred limit warning.
It operates as following warning table and the LED flashing cycle is 400ms.
Warning
status
Warning type
Description
Motor
status
Torque
status
w1
+Software limit
When normal direction(CW) software limit is
ON
Stop
Remain
w2
-Software limit
When reverse direction(CCW) software limit
is ON
w3
+Hardware limit
When normal direction(CW) hardware limit is
ON
w4
-Hardware limit
When reverse direction(CCW) hardware limit
is ON
w5
Overload warning
When maximum load is kept connected over
10sec
(motor or driver can be overheated)
Remain
Remain
※
Other warning can be occurred during Overload warning.