2 Function
© Copyright Reserved Autonics Co., Ltd.
13
2.2
Remote I/O Specification
2.2.1
Remote I/O in 1 station occupied
n indicates the address assigned to the master station by the station number setting.
RY(M
→
S)
Signal
Description
RX(S
→
M)
Signal
Description
RYn0
Servo On/Off
Servo On/Off
RXn0
Servo On/Off
Servo On/Off
RYn1
EMG
Emergency stop
RXn1
EMG
Emergency stop
RYn2
Home
Home search
RXn2
Home End
Home search end
RYn3
Reset
Reset
RXn3
Alarm
Alarm
RYn4
Alarm Reset
Alarm reset
RXn4
In-Position
In-Position
RYn5
+Run
+ direction running RXn5
Warning
Warning
RYn6
-Run
- direction running RXn6
Running
Running
RYn7
PR Start
Program running
RXn7
PR Running
Program running
RYn8
PR Single
Start
Program single
step running
RXn8
PR Single
Running
Program single step
running
RYn9
PR Pause
Program pause
RXn9
-
Disable
RYnA
PR Stop
Program running
stop
RXnA
RYnB
ABS
Absolute position
running
RXnB
ABS Running
Absolute position
running
RYnC
INC
Relative position
running
RXnC
INC Running
Relative position
running
RYnD
Position Reset Position reset
RXnD
Position Reset
Success
Position reset success
RYnE
Read Request Read request
RXnE
Read Success Read success
RYnF
Write Request Write request
RXnF
Write Success Write success
RYn0
STOP
Stop
RX(n+1)0
Read Error
Read error
RY(n+1)1 to
RY(n+1)F
-
Disable
RX(n+1)1
Write Error
Write error
RX(n+1)2 to
RX(n+1)F
-
Disable