3 Driving operation
© Copyright Reserved Autonics Co., Ltd.
23
3.1.1
Number of occupied stations
The driver is available to switch the number of occupied stations by switch setting.
Set the number of occupied CC-Link stations according to the system used.
Set the switch setting before supply power to the driver.
In case of changing the number of occupied stations, the power must be resupplied to the
driver.
Setting switch Setting CC-Link station setting
ON
2 stations occupied
OFF
1station occupied
3.1.2
Station number, Comm. speed setting
The driver is available to set the station number and communication speed by switch setting.
Set the switch setting before supply power to the driver.
In case of changing the station number or communication speed, the power must be
resupplied to the driver.
Set the CC-Link communication speed with B-RATE switch.
Setting switch Setting Comm. speed (bps) Setting Comm. speed (bps)
0
156k
5
Disable
1
625k
6
2
2.5M
7
3
5M
8
4
10M
9
Set the CC-Link station number with STATION NO. switch.
Setting switch Setting
Station
No. (×10)
Setting switch Setting
Station
No. (×1)
×10
0
0×10
×1
0
0
1
1×10
1
1
2
2×10
2
2
3
3×10
3
3
4
4×10
4
4
5
5×10
5
5
6
6×10
6
6
7
7×10
7
7
8
8×10
8
8
9
9×10
9
9