2 Function
20
© Copyright Reserved Autonics Co., Ltd.
Stop [RY(n+1]0]
Stop operation.
OUT0 to 6 [RY(n+2]0 to 6]
Used for output port ON/OFF.
STEP0 to 5 [RY(n+2]7 to C]
Set 1 step for index mode running.
The steps can be set 0 to 63 with the combination of 6 bit.
STEP No. Step5 Step4 Step3 Step2 Step1 Step0
STEP 0
0
0
0
0
0
0
STEP 1
0
0
0
0
0
1
STEP 2
0
0
0
0
1
0
…
STEP 61
1
1
1
1
0
1
STEP 62
1
1
1
1
1
0
STEP 63
1
1
1
1
1
1
Monitor Request [RY(n+2]D]
Request monitoring execution.
When entering the Monitoring group’s command code write data number on [Rwwm+6
to 7]Monitor1 to 2. The data will be displayed on [Rwrn+4 to 5]Monitor1, [Rwrn+6 to
7]Monitor2