Alarm Reset [RYn4]
Reset the Alarm.
Only available when Alarm[RXn3] is ON.
+RUN [RYn5]
Rotate to CW(+direction).
Stop when +RUN[RYn5] is OFF or STOP[RY(n+1)0] is ON.
-RUN [RYn6]
Rotate to CCW(-direction).
Stop when -RUN[RYn6] is OFF or STOP[RY(n+1)0] is ON.
PR Start [RYn7]
Start program running.
While program is running, Running[RXn6] and PR Running[RXn7] is ON.
PR Single Start [RYn8]
Start program single step running.
Execute program single step running depend on index mode step selection [RY(n+2)7 to
RY(n+2)C].
While program is running, Running[RXn6] and PR Running[RXn8] is ON.
PR Pause [RYn9]
Pause the program running.
When the pause signal is applied during the program mode running, it stops after
completing the current step.
“PR Start[RYn7]” command is applied after pause, program running restarts from the
next step after the stopped step.