Parameter Parameter Name
Description
GSD8-
240-5C
All other
GSD8
drives
42
Inhibit Configuration
This Parameter determines the accel/decel profile of the GSD8 when it is
going into and out of “Inhibit” Mode. There are 4 possible settings:
• Mode 0: No Accel/Decel
When going into Inhibit, the GSD8 will immediately shut off its output,
disregarding any Decel setting, and when coming out of Inhibit, the
GSD8 will immediately return to its Target Speed, disregarding any
Accel setting. This is exactly like the “E-Stop” behavior.
• Mode 1: Decel Only, No Accel
When going into Inhibit, the GSD8 will Decel to a stop using the
setting in Parameter 24, but when coming out of Inhibit, the GSD8 will
immediately return to its Target Speed, disregarding any Accel setting.
• Mode 2: Accel Only, No Decel
When going into Inhibit, the GSD8 will immediately shut off its output,
disregarding any Decel setting, but when coming out of Inhibit, the
GSD8 will Accelerate to its Target Speed, using the Accel setting in
Parameter 23.
• Mode 3: Use Both Accel and Decel
When going into Inhibit, the GSD8 will Decel to a stop using the
setting in Parameter 24, and when coming out of Inhibit, the GSD8 will
Accelerate to its Target Speed, using the Accel setting in Parameter 23.
43
Disable User Input
1 (IN1) in Manual
Mode
When setting this parameter to a value of 1, the IN1 will be disabled
when the unit is put into manual mode. If the value is set to 0 then the
IN1 will work in both manual and auto modes.