background image

ATS Series Installation Manual

17

18. Opener Safety & Security

18.1 Your Door CAN NOT be used by the opener when:

a. There is a locking device installed.

b. There is a power failure.

18.2 Your Door CAN be used when:

a. There is an emergency, by disengaging the opener.

b. There is a power failure, by disengaging the opener.

 

18.3 To Disengage the Opener:

a. It is recommended to do so with the door in the closed position.

b. Pull the manual release cord towards the door, until you hear a click.

c. Move the door manually.

18.4 To Re-Engage the Opener:

a. Check the door has not been locked by a locking device.

b. Pull the manual release cord away from the door, until you hear a click.

c. The door will now operate from the opener.

CAUTION: When the opener is manually disengaged, 

the door is no longer locked. To lock the door 

manually, re-engage the opener after the door is 

closed.

19. Operating your Opener

19.1 To Operate the opener:

 

a. Press the programmed transmitter button until your 

door begins to move (usually 2 seconds). Make sure 

you can see the door when you use the transmitter.

b. If you are in a vehicle you should aim the transmitter 

through your windscreen as shown.

c. Check that the door is fully open or closed before you 

drive in or away.

d. If you press the transmitter whilst the door is moving 

the door will stop. The next press of the transmitter 

will move the door in the opposite direction.

WARNING! When operating the manual 

release (while the door is open) the door 

may fall rapidly due to weak or broken 

springs, or due to being improperly 

balanced. 
Do not disengage the opener to manual 

operation with children/persons or any 

objects including motor vehicles within 

the doorway.

CAUTION: Do not use the string handle as a 

mechanism to open the door. Failure to comply may 

cause serious injury.

Содержание Syncro ATS-3

Страница 1: ...1 Sectional Door Opener Installation Manual Doc 160420_03 Released 18 03 21 ATS Series SYNCRO ATS 3 SMART SECTIONAL DOOR OPENER TEMPO ATS 2 SECTIONAL DOOR OPENER ...

Страница 2: ...less than 1 8 m install any fixed control at a height of at least 1 5 m and within sight of the door but away from moving parts permanently fix the labels warning against entrapment in a prominent place or near any fixed controls permanently fix the label concerning the manual release adjacent to its actuating member after installation ensure that the mechanism is properly adjusted and that the dr...

Страница 3: ...ues when required to lift the door as per installation instructions Fall from ladder Ensure ladder is the correct type for job Ensure ladder is on flat firm ground that will take the weight without the legs sinking Ensure user has 3 points of contact while on ladder Crush injury from unsecured door Place a 2 metre exclusion zone around area under the door while it is unsecured Follow the installat...

Страница 4: ...ngle which MUST be securely fastened to a structural support You will need to locate the structural beams in the ceiling which are generally 400mm apart ii Does it have exposed beams The opener is mounted to a perforated angle which must be securely fastened to a structural support like the exposed beams You may need to install a 40mm thick board not supplied between structural supports b Look at ...

Страница 5: ...LUS 15 2 x Track Bracket 16 1 x Pre Assembled Rail 10 00 min MINIMUM HEAD ROOM FOR STEEL RAIL 57mm DOORS HIGHEST POINT Rail no Extension Kit 3156mm Rail 1 Extension Kit 3946mm Rail 2 Extension Kits 4736mm Rail refers to 3160 rail 170mm 3156mm 3374mm 150mm 353mm 15 1 16 5 4 6 7 12 8 14 11 9 13 10 5 Position Perforated Angle 5 1 The Opener a MUST BE installed in a dry position protected from weather...

Страница 6: ... ensue causing serious personal injury and or property damage DO NOT DO IT YOURSELF If sufficient structural support can not be found contact a door professional for installation DIY c Using step ladder and a level transfer this height to the wall above the door and mark a line 60mm above it across the centre line 7 2 Mounting The Wall Bracket a Draw two lines extending 21 5mm from each side of th...

Страница 7: ... to the door requires 2 x perforated L shape metal strips and 2 x shorter perforate L shape metal drop down strips Not supplied 9 Mounting Brackets and Arms 9 1 Mounting The Door Bracket a The door bracket locator 7 is placed over the door bracket 8 on the door s centre line one third down the top panel and mounted using M6 or equivalent screws not supplied b STEEL DOORS ONLY Bracket can be welded...

Страница 8: ...rews not supplied 10 2 Mounting the Bracket The transmitter and receiver need to be placed in line of sight with the beam 100mm above the ground level as per AS NZS 60335 2 95 2012 Amendment 2 2018 This can be achieved by ensuring the bottom of the receiver and transmitter are 65mm above ground level They should also be placed as close as possible to the door opening with the receiver RX in shade ...

Страница 9: ...ad 400N 400N Nominal force 200N 20kg 200N 20kg Receiver type Multi frequency UHF FM 433 47 433 92 434 37MHz Multi frequency UHF FM 433 47 433 92 434 37MHz Receiver code storage capacity 64 X 4 button Transmitters 64 X 4 button Transmitters Transmitter battery CR2032 3 Volts CR2032 3 Volts Main light LED Light Emitting Diodes LED Light Emitting Diodes Network connectivity Network ready Smart hub al...

Страница 10: ...make a change press and hold the CLOSE button and by pressing the STOP SET button on the opener it will cycle through all three speed modes as shown in table iii Once at the desired speed release the CLOSE button iv To set the close limit inch the door by making single presses of the CLOSE button to the desired position We recommend the CLOSE limit position being the first point of contact of the ...

Страница 11: ...ing the Door Re profiling is a simplified way of re learning the travel characteristic of a previously setup Limit Switch travel installation Re profiling can be used when the travel characteristics of the door change due to mechanical adjustments etc To initiate a re profile a Limits must be set b Press the MODE button repetitively until the GEAR LED is lit c Press and hold the CLOSE button for t...

Страница 12: ...not reverse readily when closing or stop when opening put the door into manual by pulling down on the manual release string to disengage the motor and contact 13 62 63 for support 13 3 Test the Manual Door Operation Periodically disengage the opener and manually operate the door The door must be smooth to operate by hand The force required on the bottom rail should not exceed 20kg CAUTION Take car...

Страница 13: ... to countdown as soon as the door is fully open This function is useful in case the safety beam does not get triggered ii Safety Beam triggered auto close the door will auto close after a programmed time In this mode the timer starts counting down only when the safety beam is triggered ie car leaving the garage To enable the Auto Close function a Press the MODE button repetitively until the GEAR L...

Страница 14: ... instructions above Test the transmitter button b Mount the transmitter in a convenient location yet out of reach of children and at least 1 5m off the ground c Make sure the door is visible from this location 15 5 Remotely Coding Transmitters Using this method transmitters can be coded without access to the opener s control panel as long as a pre coded transmitter is available a Take any pre code...

Страница 15: ... your phone app smart hub and opener to your home network a Download the ATA App b Ensure the WiFi router is within range of the opener c On the opener press the MODE button repetitively until the NETWORK LED is lit d Press and hold the OPEN button on the opener for 4 seconds The NETWORK LED will turn purple when Hot Spot is Active e Go to phone settings then WiFi and select ATA000000 f Open App a...

Страница 16: ...ersonal injury DO NOT attempt any garage door adjustment DO NOT use if repair or adjustment is needed Call for a professional garage door service CAUTION Emergency access If your garage has no pedestrian entrance door an emergency access device should be installed This accessory allows manual operation of the garage door from outside in case of power failure Entrapment under operating door Watch t...

Страница 17: ...ck the door manually re engage the opener after the door is closed 19 Operating your Opener 19 1 To Operate the opener a Press the programmed transmitter button until your door begins to move usually 2 seconds Make sure you can see the door when you use the transmitter b If you are in a vehicle you should aim the transmitter through your windscreen as shown c Check that the door is fully open or c...

Страница 18: ...ow Enables Load Diagnostics Mode 7 MODE STATUS LED Yellow Illuminates when in Diagnostics Mode 8 BATTERY STATUS LED Yellow Illuminates when battery is charged and flashes when battery is charging in use or battery failed Battery function not available with ATS 2 model 9 REMOTE CONTROL STATUS LED Red Flashes on remote lockout and flickers on remote control activity 10 ADJUSTMENT LED Yellow Flashes ...

Страница 19: ...Make sure you can see the door when you use the transmitter Check the battery status by pressing a button flashing or no light battery need changing Aim the transmitter through the windscreen The Courtesy light does not work LED has failed Change LED The door reverses for no apparent reason This may occur occasionally from environmental conditions such as areas that are windy dusty or have extreme...

Страница 20: ...d button on transmitter for more than five seconds and the door will start closing 3 NOT AVAILABLE 4 Wireless PE battery is low Change PE Battery 5 NOT AVAILABLE 6 Maintenance is due after pre set number of cycles Contact dealer to arrange service 7 Standby battery is faulty Contact 1300 769 850 within Australia for assistance 8 Door was obstructed Clear away any obstructions and test door opens c...

Страница 21: ...or bolts screws cables and connectors 3 Adjustment of spring tension to limit spring fatigue 4 Adjustment of opener travel limits and force margin to ensure the door opens and closes to specification 5 Assessment and adjustment of safety components and accessories including safety beams Auto Lock and Safe Lock if installed 6 Assessment of the door alignment and the diagnosis of irregular operation...

Страница 22: ...tter button Check Light Status table to determine if battery needs replacing Light Status Battery Status Solid OK Flashing Requires replacement No light Requires replacement Use a pen to push the battery down through the side opening to release battery Use finger nails to separate the transmitter casing to expose circuit board Use a non metallic object e g pen to remove the battery Some batteries ...

Страница 23: ... mode BATTERY LED 4 off solid flashing rapid flashing Battery not used not fitted Battery charged Battery charging when connected to power without power battery in use holding STOP for 10s will shutdown Battery failed REMOTE CONTROL STATUS LED 5 flashing rapid flashing Remote lockout Remote Control Activity NETWORK LED 6 ATS 3 Only 1 flash then pause 2 flashes then pause solid rapid flashing alter...

Страница 24: ...ntal conditions such as windy or dusty areas and areas with extreme temperature changes To Increase Decrease Force Pressure a Press the MODE button repetitively until the GEAR LED is flashing b The LED will start flashing with one flash every second c Press the STOP STEP button and the MODE button LED and the TRANSMIT LED will be lit and the GEAR LED will flash once every second d By pressing the ...

Страница 25: ...overshoots press the OPEN button 1 on the remote to move the door in the OPEN direction vi When the door is at the desired CLOSE position press the SET button 2 the GREEN LED on the OPEN button will now flash E Setting limits via Transmitter Button 1 inch Open Button 2 Set Button 4 inch Close OPEN limit i Using the programmed transmitter press and hold the button 1 to open To inch the door single ...

Страница 26: ...ain courtesy light turns solid ON or OFF Main courtesy light ON Tilt type J Type only Main courtesy light OFF Sectional type c Press and hold STOP SET for 6 seconds to change the door type until the main courtesy light turns solid ON or OFF If required repeat step b to check the door type selected d Press MODE button to exit the door selection mode Proceed to Section 12 to set the limits G Setting...

Отзывы: