ATS Series Installation Manual
10
12.1 Set the Limit Positions and adjust drive speed:
The Limit Positions can vary due to site conditions, such as uneven
ground. When setting the Close limit, ensure the position is when the
door makes first contact with the ground. Alternatively for the Open
limit the position should be at the height of the garage opening.
NOTE: The drive speed is set to the fastest setting by default. This
may not be suitable for larger doors or for single piece doors. For
tilt doors (J-Type only), please refer to Appendix G for initial setup.
a. Switch power on and the BLUE LED on the CLOSE button
will start to flash and the GEAR
LED is lit to indicate that the
opener is ready to set the Close travel limit.
b. Press either the CLOSE
or OPEN
button to move the
door to the halfway point.
WARNING! In setting the close limit position,
do not force the door into the floor with
excessive force, as this can interfere with
the ease of operation of the manual release
mechanism.
Door Opener
Speed Mode
STATUS
MAIN LIGHT
Fast (Default)
On
3 Flash
Medium
On
2 Flashes
Slow
On
1 Flashes
WARNING! The door will automatically close,
open and close again after the next step.
Ensure that nothing is in the door’s path.
12. Setting Limits
CLOSE limit:
i. Press and hold the CLOSE button
to start closing
the door, taking note of the speed the door moves.
ii. If the close speed is not suitable, to make a change,
press and hold the CLOSE button and by pressing the
STOP / SET button on the opener it will cycle through
all three speed modes as shown in table.
iii. Once at the desired speed, release the CLOSE button.
iv. To set the close limit, inch the door by making single
presses of the CLOSE button
to the desired
position. We recommend the CLOSE limit position
being the first point of contact of the rubber strip ( at
the bottom of the door) with the ground.
v. If the door overshoots, press the OPEN button
to
move the door in the OPEN direction.
vi. When the door is at the desired CLOSE position, press
the STOP / SET button on the opener, the GREEN
LED on the OPEN button will now flash.
OPEN limit:
i. Press and hold the OPEN button
to start opening
the door, taking note of the speed the door moves.
ii. If the open speed is not suitable, to make a change,
press and hold the OPEN button and by pressing the
STOP / SET button on the opener it will cycle through
all three speed modes as shown in table.
iii. Once at the desired speed, release the OPEN button.
iv. Continue inching the door to the desired position.
v. To set the open limit, inch the door by making single
presses of the OPEN button
to the desired
position. We recommend the OPEN limit position
being the height of the garage opening.
vi. If the door overshoots, press the CLOSE button
to move the door in the CLOSE direction.
vii. When the door is at the desired OPEN position, press
the STOP / SET button The door will now automatically
close and open to calculate the safety obstruction
settings.
Refer to Appendix B & C for adjustments to
margins.
tip