8
GDO-9v2 SecuraLift®
Owner Installation Instructions
Operating controls
01
02
03
04
05
06
07
08
09
10
11
P.E. Shunt.
The shunt has to be removed when connecting a Photo Electric Beam.
NOTE:
P.E. Shunt must only be removed when P.E. Beams are being connected, otherwise the opener will
malfunction.
Terminal Block.
24V PWR is used to power devices such as:
PE (Input) for photo electric beam for safety and auto-close function.
LGT (Input) allow hard wired external trigger for the opener’s courtesy light.
O/S/C INPUT is used for the connection of a wired switch (momentary contact). This switch
can then be used to open, stop or close the door. Install the wall switch in a location where
the switch is out of reach of children and the garage door is visible.
SET
button (yellow) is used during the installation phase together with the Open and MINUS (-) buttons to
set the door limit positions. The Set button is also used to re-initialize the Opener.
LIGHT CODE
button (white) is used for storing or erasing the transmitter button (code) you wish to use
to switch the courtesy light on the opener on or off.
CODING LED
(red) light fl ashes when a code is being stored or when a transmitter button is pressed.
OPERATE
button (Yellow) is used during installation to test the open, stop and close cycles for the
opener. The opener has to be initialised by the Reset button to make the O/S/C button operable.
DOOR CODE
BUTTON (blue) is used for storing or erasing transmitter buttons for door operation
DOOR STATUS LED
(Yellow)
MINUS
(-) button (red) is used during installation to help set the close limit position. Pressing and holding
this button will move the door in the close direction. Movement stops when the button is released.
NOTE:
The safety obstruction detection is inoperable when the CLOSE button is used to move door..
PLUS
(+) button (green) is used during installation to help set the open limit position. Pressing and holding
this button will move the door in the open direction, releasing stops the door.
NOTE:
The safety obstruction detection is inoperable when the PLUS (+) button is used to move door.
CLOSE LIMIT LED
(red) the LED is very helpful during installation. It illuminates and fl ashes when the
door is closing and remains steady on when the close limit position has been reached.
OPEN LIMIT LED
(green) the LED is very helpful during installation. It illuminates and fl ashes when the
door is opening and remains steady on when the open limit position has been reached.
AUTO CLOSE TIME
button (White) is used to adjust the auto close time. While holding in the AUTO
CLOSE TIME button and then pressing the PLUS (+) button the time is increased. Each press will increase
the time by 5 seconds. Pressing the MINUS (-) button will decrease the time.
FORCE MARGIN SET
Button: The obstruction force margin is set automatically during installation. The
margin can be adjusted manually using the Force Margin Set button (White). Holding the Force Margin Set
button and pressing PLUS (+) or MINUS (-) buttons will increase or decrease the amount of force. The Force
Margin Set should only be used if environmental factors (wind, etc.) affect the door’s operation.
J13 CONNECTOR
onto this the shunt supplied with SmartSolar™ kit must be fi tted for solar
operation.
•
»
»
»
12
13
14
15