Owner Installation Instructions
GDO-9v2 SecuraLift®
27
Default Settings & Specifi cations
Factory default settings
Default
Step
Maximum
Maximum motor run time
25 Secs.
-
-
Courtesy light time
3 Mins.
10 Secs.
4 Mins.
Obstruction force margin
8
1
20
Auto close time
0 Secs
1 Sec.
4 Mins.
Technical specifi cations
Power supply
230V - 240V AC 50Hz
Transformer rating
24V DC
Standby power
2.2 Watts
Motor power
100 Watts
Motor type
24V DC permanent magnet
Shuttle travel distance in the C-Rail
2.8m approx (standard)
Maximum shuttle travel distance in the C-Rail
5m (with extended C-Rail)
Maximum door opening:
Width:
Height:
Weight:
5500mm (16.5m
2
)
3000mm
100 kg
Minimum Clearance
(Bottom of C-Rail to highest point of door travel)
25mm
Short term peak force
800N (80kg)
Lift force
500N (50kg)
Nominal force
150N (15kg)
Receiver type
UHF 433.92 MHz AM Receiver
Receiver code storage capacity
24 x 4 button transmitter codes
Transmitter frequency
~= to 433.92 MHz
Coding type
Multi-frequency Code hopping
Number of code combinations
Over 4.29 billion random codes
Code generation
Non-linear encryption algorithm
Transmitter battery
A23 Alkaline 12 Volts
Courtesy light
Festoon style lamp
Controller fuse
10A slow blow
NOTE:
Intermittent operations may occur in areas which experience very strong winds. The strong wind
puts extra pressure on the door and tracks which may in turn trigger the safety obstruction detection system
intermittently.