36
Easy Slider - Sliding Gate Opener
Owner Installation Instructions
Symptom
Possible cause
Remedy
Gate will not operate
Mains power not switched on
Door is obstructed
Door is locked or motor jammed
Door tracks/hardware damaged
Switch on mains power
Remove obstruction
Unlock door or remove jam
Door requires service/repair by
qualified technician
Gate starts to close but
automatically reverses to
open position
Adverse weather conditions (wind
or cold) causing gate to stiffen and
become tight in the tracks
Possible obstruction in
the gateway
Increase force margin setting.
See page XX
Remove obstruction
Gate does not operate from
transmitter
*See note
Transmitter code not stored
in memory
Flat battery - LED flashes
Code transmitter in to openers
memory. Refer to page XX
Replace battery - A23 Alkaline 12V
Gate will not close fully
Gate limits position need to
be reset
Reset limits positions. See Page XX
Gate will not open fully
Gate limits position need to
be reset
Reset limits positions. See Page XX
Opener beeping and gate does
not move
Disengagement lever opening
Disengage connector not
plugged in
Close disenage lever and lock
in place
Plug connector into J10 socket
on board
Auto close not working
PE Beam or wiring faulty
PE Beam not aligned correctly
PE Beam is obstructed
Gate obstructed when closing
Auto close time not set
Auto close mode not set
Repair PE Beam or replace wiring
Re-align optics
Remove obstruction from the path
of PE
Remove obstruction
See page XX
See page XX
PLEASE NOTE:
Some areas may be prone to excessive radio interference brought on by devices such as cordless telephones,
wireless stereo headphones and baby monitors. It is possible that these devices could cause a degree of
interference such as to greatly reduce the range of the transmitter. In such an instance please contact your ATA
dealer for an alternative frequency replacement kit. As this is not a warrantable situation but an environmental
issue charges may apply for the changeover.