Dominator Tempo & Syncro Instruction Manual

Overhead Garage Door Operator

4008033

Conforms to: 

 ANSI/CAN/UL325  

Tested to comply 

with Part 15 of the 

FCC Rules

Doc # 160416_00
Part #  87406
Released 08/09/20

SYNCRO ATS-3

DOMINATOR TEMPO ATS-2AM

SECTIONAL DOOR OPENER

SYNCRO ATS-3

DOMINATOR SYNCRO ATS-3AM

SMART SECTIONAL DOOR OPENER

Содержание Dominator Syncro ATS-3AM

Страница 1: ...ead Garage Door Operator 4008033 Conforms to ANSI CAN UL325 Tested to comply with Part 15 of the FCC Rules Doc 160416_00 Part 87406 Released 08 09 20 SYNCRO ATS 3 DOMINATOR TEMPO ATS 2AM SECTIONAL DOOR OPENER SYNCRO ATS 3 DOMINATOR SYNCRO ATS 3AM SMART SECTIONAL DOOR OPENER ...

Страница 2: ...ns for future reference ELECTROCUTION To reduce the risk of electric shock this equipmenthasagroundingtypeplugthathasathird grounding pin This plug will only fit into a grounding type outlet If the plug does not fit into the outlet contact a qualified electrician to install the proper outlet Do not change the plug in any way This operator is not equipped for permanent wiring Contact a qualified el...

Страница 3: ...Auto Close 14 6 5 1 Obstruction Detection Test 14 6 5 2 Test the Close Cycle and Safety Reversal 14 6 5 3 Testing the Open Cycle 14 6 5 4 Test the Manual Door Operation 14 6 5 5 Auto Close 14 6 6 Coding Transmitters 15 6 6 1 Setting Remote Control Transmitter Codes 15 6 6 2 Install Wireless Wall Mounted Remote Transmitter 16 6 6 5 Remotely Coding Remote Control Transmitters 16 6 6 3 Erasing All Re...

Страница 4: ... outlet If the plug does not fit into outlet contact a qualified electrician to install the proper outlet Do not change the plug in any way If the power cord is damaged it must be replaced by the manufacturer its service agent or a similarly qualified person in order to avoid a hazard Connect the power cord only to properly earthed mains If an extension lead must be used make sure it is a 3 core l...

Страница 5: ... FM Receiver Receiver code storage capacity 14 X 4 button transmitter codes 14 X 4 button transmitter codes 14 X 4 button transmitter codes 14 X 4 button transmitter codes Transmitter frequency 433 47MHz 433 92MHz 434 37MHz 433 47MHz 433 92MHz 434 37MHz 433 47MHz 433 92MHz 434 37MHz 433 47MHz 433 92MHz 434 37MHz Coding type TrioCode128 TrioCode128 TrioCode128 TrioCode128 Number of code combination...

Страница 6: ... 6 MODE Yellow Enables Load Diagnostics Mode 7 MODE STATUS LED Yellow Illuminates when in Diagnostics Mode 8 BATTERY STATUS LED Yellow Illuminates when battery is charged and flashes when battery is charging in use or battery failed Battery function not available with ATS 2 model 9 REMOTE CONTROL STATUS LED Red Flashes on remote lockout and flickers on remote control activity 10 ADJUSTMENT LED Yel...

Страница 7: ...rm door attachment 5 1 x Straight arm door attachment 6 1 x Wall bracket TS01 7 1 x Door bracket Locator 8 1 x Door bracket 9 3 x Pin Snap SSP 8 ZNU 31080 10 2 x Hex Head screw M8x25 11 1 x Pin 0890 12 2 x Clevis Pin 0829 13 2 x Hex Serration flange nut M8 14 4 x Hex flange screw taptite S M4 x 10 15 1 x Wired Safety Beam kit PLUS 16 2 x Track Bracket 17 1 x Pre Assembled C Rail 10 00 min MINIMUM ...

Страница 8: ...Operator When the door has been disengaged from the opener the shuttle assembly attached to the manual release cord can move up and down the chain Re engage the opener Fig 5 1 preferably with the door open to waist height and then press the programmed transmitter button the motor will run until the shuttle assembly engages the chain index on the chain you will hear it click into place Then the doo...

Страница 9: ...RGENCY RELEASE MOUNT THE EMERGENCY RELEASE WITHIN REACH BUT AT LEAST 6 FEET ABOVE THE FLOOR AND AVOIDING CONTACT WITH VEHICLES TO AVOID ACCIDENTAL RELEASE 5 DO NOT CONNECT THE OPENER TO SOURCE OF POWER UNTIL INSTRUCTED TO DO SO 6 LOCATE THE CONTROL BUTTON i WITHIN SIGHT OF DOOR ii AT A MINIMUM HEIGHT OF 5 FEET ABOVE FLOORS LANDINGS STEPS OR ANY OTHER ADJACENT WALKING SURFACE SO SMALL CHILDREN ARE ...

Страница 10: ...e wall with an appropriate bit g Secure to the wall using i IF CONCRETE OR BRICK 8mm 5 6 loxins dynabolts ii IF TIMBER wood screw 20 or similar minimum 1 97 50mm long Fig 6 2 2 WARNING Make sure concrete brick wall or timber lintels are solid and sound so as to form a secure mounting platform 6 2 3 Attach the C Rail to the Wall Bracket a Leave the drive unit in its packing box on the floor for pro...

Страница 11: ...oor s centre line one third down the top panel and mounted using M6 or equivalent screws not supplied Fig 6 2 6 b STEEL DOORS ONLY Bracket can be welded in place NOTE As various types of doors exist if in doubt about the strength of the door reinforcement may need to be added to the frame of the door panel where necessary Damage to the door panel may occur if the bracket is installed incorrectly o...

Страница 12: ... and no lower than 5 above the floor level The mounting surface should be rigid 6 3 3 PE Assist Alignment a Wire the PE Beams as per Wiring Diargram Fig 6 3 2 b After the beams are installed the beam alignment feature of the opener can be used c Turn power on to the opener d Align the safety beams by moving them per Fig 6 3 3 and using the main light as a guide i bright aligned ii dull not aligned...

Страница 13: ...s and hold the CLOSE button to start closing the door taking note of the speed the door moves ii If the close speed is not suitable to make a change press and hold the CLOSE button and by pressing the STOP SET button on the opener it will cycle through all three speed modes as shown in table iii Once at the desired speed release the CLOSE button iv To set the close limit inch the door by making si...

Страница 14: ...red auto close the door will auto close after a programmed time In this mode the timer starts counting down only when the safety beam is triggered ie car leaving the garage To enable the Auto Close function a Press the MODE button repetitively until the GEAR LED starts flashing b Press the OPEN button until the GEAR LED flashes i two 2 times to get to PE auto close or ii three 3 times to get to st...

Страница 15: ...INTERFERENCE TO RADIO OR TELEVISION RECEPTION WHICH CAN BE DETERMINED BY TURNING THE EQUIPMENT OFF AND ON THE USER IS ENCOURAGE TO TRY TO CORRECT THE INTERFERENCE BY ONE OR MORE OF THE FOLLOWING MEASURES REORIENT OR RELOCATE THE RECEIVING ANTENNA INCREASE THE SEPARATION BETWEEN THE EQUIPMENT AND RECEIVER CONNECT THE EQUIPMENT INTO AN OUTLET ON A CIRCUIT DIFFERENT FROM THAT TO WHICH THE RECEIVER IS...

Страница 16: ...yet out of reach of children and at least 5 feet off the ground Fig 6 6 3 d Make sure the door is visible from this location 6 6 5 Remotely Coding Remote Control Transmitters Using this method transmitters can be coded without access to the opener s control panel as long as a pre coded transmitter is available a Take any pre coded transmitter Press the button for the function to be duplicated and ...

Страница 17: ...ire 4A to the red plus terminal A on Battery A then connect coupling black wire 4B to the black minus terminal B on Battery B d Close the cover securing with screw and reconnect power NOTE Batteries may take up to 24 hours to charge fully after initial installation 6 7 2 Test the Opener a Press either the OPEN or CLOSE button to test the battery backup installation b Whilst door is in motion disco...

Страница 18: ... door can cause serious personal injury or damage to property Your opener must be fitted with SAFETY BEAMS Safety Beams detect any obstructions in the door s path and override automatic operation if one presents These must be installed as in accordance with UL 325 and CSA C222 2 No 247 This is in addition to regular professional servicing and monthly obstruction tests as detailed in your opener s ...

Страница 19: ...JUSTING EITHER THE FORCE OR THE LIMIT OF TRAVEL RETEST THE DOOR OPENER FAILURE TO ADJUST THE OPENER PROPERLY INCREASES THE RISK OF SEVERE INJURY OR DEATH 6 FOR PRODUCTS HAVING AN EMERGENCY RELEASE WHEN POSSIBLE USE THE EMERGENCY RELEASE ONLY WHEN THE DOOR IS CLOSED USE CAUTION WHEN USING THIS RELEASE WITH THE DOOR OPEN WEAK OR BROKEN SPRINGS ARE CAPABLE OF INCREASING THE RATE OF DOOR CLOSURE AND I...

Страница 20: ...oor is fully open or closed before you drive in or away d If you press the transmitter whilst the door is moving the door will stop The next press of the transmitter will move the door in the opposite direction 7 1 2 Replacing the Battery 3V Lithium Battery CR2032 a To test the battery is working press and hold a transmitter button Check Light Status table to determine if battery needs replacing L...

Страница 21: ...tructed on opening or stopped 6 MODE Yellow Enables Load Diagnostics Mode 7 MODE STATUS LED Yellow Illuminates when in Diagnostics Mode 8 BATTERY STATUS LED Yellow Illuminates when battery is charged and flashes when battery is charging in use or battery failed Battery function not available with ATS 2 model 9 REMOTE CONTROL STATUS LED Red Flashes on remote lockout and flickers on remote control a...

Страница 22: ... motor vehicle Make sure you can see the door when you use the transmitter Check the battery status by pressing a button flashing or no light battery need changing Aim the transmitter through the windscreen The Courtesy light does not work LED has failed Change LED The door reverses for no apparent reason This may occur occasionally from environmental conditions such as areas that are windy dusty ...

Страница 23: ...ns Test Door If unable to move the door and suspect beam is faulty enter Safety Beam Emergency Close by pressing and holding a pre coded button on transmitter for more than five seconds and the door will start closing 3 NOT AVAILABLE 4 Wireless PE battery is low Change PE Battery 5 NOT AVAILABLE 6 Maintenance is due after pre set number of cycles Contact dealer to arrange service 7 Standby battery...

Страница 24: ... Diagnostics mode BATTERY LED 4 off solid flashing rapid flashing Battery not used not fitted Battery charged Battery charging when connected to power without power battery in use holding STOP for 10s will shutdown Battery failed REMOTE CONTROL STATUS LED 5 flashing rapid flashing Remote lockout Remote Control Activity NETWORK LED 6 ATS 3AMB Only 1 flash then pause 2 flashes then pause solid rapid...

Страница 25: ...r or press MODE to exit adjustment mode D Battery Functions a Holding the STOP button for 10secs when running from battery backup will shut the PCB down so as to reduce battery current consumption to a minimum b Holding the STOP button for 4secs when a battery is fitted and running from mains power will cause the controller to test the battery state to determine if it is disconnected open circuit ...

Страница 26: ...e speed modes as shown in table iii Once at the desired speed release the remote button 4 iv Continue inching the door to the desired position We recommend the CLOSE limit position being the first point of contact of the rubber strip at the bottom of the door with the ground v If the door overshoots press the OPEN button 1 on the remote to move the door in the OPEN direction vi When the door is at...

Страница 27: ... to limit set up the opener can be set to J Type Tilt Profile This process allows the opener to pre set to J Type settings where the limit is not greater than 1500mm If J Type is selected the speed is customised and cannot be changed a Press the MODE button repetitively until the GEAR LED starts flashing b Press and hold STOP SET button for 2 seconds to check the door type until the main courtesy ...

Страница 28: ...Automatic Technology America VIneyard Centre II 1452 Hughes Road Grapevine Texas 76051 United States of America P 1 817 873 5076 W www ata america com ...