Diamond PD
Power Drive
: Instruction Manual
Dominator Tempo & Syncro Instruction Manual
ATS-3AM & ATS-2AM
11
© Copyright 2019
Fig.6.2.4
WARNING! The operator must be securely fastened
to a structural support of the garage. Failure to
fasten the operator correctly may lead to operator
failure causing serious personal injury and/or property
damage.
ELECTROCUTION! This operator is not equipped for
permanent wiring. Contact a qualified electrician to
install a suitable receptacle if one is not available.
6.2.4 Securing the Powerhead Perforated Angle or equivalent
a. Measure across the ceiling from the centre point 3155mm (+/- 50mm) to
find a supporting beam.
b. Create a perforated angle which best suits your site. Use a hack saw to
cut the L shape metal strips. Secure the perforated angle to a supporting
beam using diagrams shown below
(
Fig.6.2.4 & Fig.6.2.5)
.
c. Raise the drive unit to the ceiling mounted perforated angle and secure
with M8x20mm screws and nuts (not supplied). Strips should not extend
more than 0.708” 18mm below centre of drive unit mounting holes.
d. To prevent moisture on the C-rail running into the powerhead it is
recommended a strip of silicon sealant is placed across the top of the
C-rail just before the opener.
Fig.6.2.5
Fig.6.2.6
Fig.6.2.7
6.2.6 Mounting Door Bracket
a. The door bracket locator
7
is placed over the door bracket
8
, on the
door’s centre line one-third down the top panel and mounted using M6
or equivalent screws (not supplied)
(Fig 6.2.6)
,
b. STEEL DOORS ONLY: Bracket can be welded in place.
NOTE:
As various types of doors exist, if in doubt about the strength of
the door, reinforcement may need to be added to the frame of the door
panel where necessary. Damage to the door panel may occur if the bracket is
installed incorrectly on a panel with insufficient strength. The door operator
warranty does not cover damage caused by the operator to the door and/
or door panel.
WARNING! connecting the bent arm other way
around may damage the door.
6.2 Mounting Operator for a Track Type Door
Ceiling Beams that run towards the door requires:
1 x perforated L shape metal strip and
2 x shorter perforate L shape metal drop down strips.
Ceiling Beams that run parallel to the door requires:
2 x perforated L shape metal strips and
2 x shorter perforate L shape metal drop down strips.
8
7
7
12
9
4
13
6
10
9
12
8
5
A
6.2.7 Attaching the Arms
a. Assemble the bent arm
4
(connecting to the door) to the right side
of the straight arm
5
with bolts
10
and nuts
13
supplied in the
accessory pack. Connect the straight arm
5
to the shuttle with a clevis
pin
12
and a pin snap
9
. Always use both bent and straight arms
(Fig
6.2.7)
.
b. Connect the assembled arm to the bracket with clevis pin
12
and pin
snap
9
. The angle “A” must be more than 10°.
IMPORTANT NOTE: If the manual
release handle is more than 5.91ft
(1.8 meters) from floor level when
the operator is installed, extend
the handle to a height 5.91ft (1.8
meters).