12
ATS-3AM & ATS-2AM
Dominator Tempo & Syncro Instruction Manual
6.3 Safety Beam Installation
6.3.1 Safety Infra-Red Beam Kit (P/N 62047)
A Safety Beam extends across the door opening. This Safety Beam is
designed to detect an obstruction while the door is closing and to send a
signal to the door operator to reverse or stop the door movement.
Install
the Safety Beam indoor only.
6.3.2 Assembling the Mounting Bracket
a. Place the round screw
3
through the Bracket
5
. Attatch the Safety
Beam Transmitter (TX) using four (4) M3 x 5 Taptite screws
4
(
Fig. 6.3.1
)
.
b. Connect the mounting bracket
2
to the Bracket
5
using the wing nut
8
onto the round screw
3
. Secure the adjustment bracket
6
to the
mounting bracket
2
using two (2) screws
3
and nuts
7
.
c. Repeat steps (a) and (b) to assemble the Safety Beam Receiver (RX).
d. Locate the Safety Beam in a strategic location in the door opening.
We recommend
that the sensor is placed no higher than 6” and no lower
than 5”above the floor level. The mounting surface should be rigid.
6.3.3 PE Assist Alignment
a. Wire the PE Beams as per Wiring Diargram
(
Fig. 6.3.2
)
.
b. After the beams are installed the beam alignment feature of the opener
can be used.
c. Turn power on to the opener.
d. Align the safety beams by moving them per
Fig 6.3.3
and using the main
light as a guide:
(i) bright = aligned
(ii) dull = not aligned or blocked
When the beams are aligned, continue with Setting Limits.
RED
BLACK
RED
BLACK
RED
BLACK
BLACK
SB1
OV
V+
SB2
OV
OSC
AUX
4
2
3
3
6
8
7
5
1
Fig.6.3.1
Fig.6.3.2
Fig 6.3.3
WARNING: When the Safety Beam is fitted, the doorway
must be clear of all obstructions and persons at all times.
Incorrect location of the safety beams may not give
safety protection at all times. Check to make sure that
the height of the beam gives maximum protection.
WARNING: Connect the Safety Beam as per diagram in
Fig 6.3.2. Tampering with the Safety Beam could result in
serious personal injury and/or property damage and will
void the warranty.
IMPORTANT NOTE: The Safety Beam must be installed and connected
before the travel limits are set.