Parameter
Min
Max
Default
Step
Unit
Menu No.
STD AUTO-CLOSE TIME
Sets and enables the standard Auto-Close time.
0.0
300.0
0.0
1.0
Sec
3.1
P.E. AUTO-CLOSE TIME Sets and enables the
P.E. triggered Auto-Close time.
0.0
60.0
0.0
1.0
Sec
3.2
PEDESTRIAN AUTO-CLOSE TIME Sets and
enables the Pedestrian Auto-Close time.
0.0
60.0
0.0
1.0
Sec
3.3
P.E. PEDESTRIAN AUTO-CLOSE TIME Sets and
enables the P.E. Pedestrian Auto-Close time.
0.0
60.0
0.0
1.0
Sec
3.4
AUTO-CLOSE AFTER CLOSE OVERLOAD
Enables Auto-Close feature after close overload
Off
On
Off
3.5
AUTO-CLOSE AFTER OPEN OVERLOAD
Enables Auto-Close feature after open overload
Off
On
Off
3.6
AUTO-CLOSE AFTER POWER - UP
Enables Auto-Close feature after power - up
Off
On
Off
3.7
P.E. Beams Triggered, Directional Auto-Close
This mode is selected by entering a non-zero time for the “
P.E. Auto-Close
” parameter. A second P.E. Beam
must be installed and connected to OPN input. Sub menu 5 : OPN I/P 2nd P.E. in Menu 7 Operating Modes must
be selected “ON” and also sub menu 4: OPN I/P N/C operation in Menu 7 Operating Modes must be selected
“ON”.
This mode is used to Auto-Close the shutter only after a vehicle has passed through the doorway to exit the
premises. The 2nd P.E. (OPN) input must be active when the P.E. input is activated in order for a P.E. triggered
Auto-Close to be activated. 3 wire P.E. BEAM recommended only.
This mode is useful for fi re and ambulance
stations etc.
Menu 4. Light Times
A light can be controlled with the addition of a relay module connected between the AUX OUT and V+ terminals
on the logic console. It will automatically turn off one (1) minute after the cycle has fi nished. The light timer is
adjustable. The light also can be activated and deactivated by pressing a transmitter button assigned to the LGT
function.
Parameter
Min
Max
Default
Step
Unit
Menu No.
ON AFTER CYCLE LIGHT TIME
Time light remains on for after a cycle
0
255
60
1
Sec
5
ON BEFORE OPEN CYCLE LIGHT TIME
Minimum time light is activated for prior to
opening
0
25.5
0
0.1
Sec
5
ON BEFORE CLOSE CYCLE LIGHT TIME
Minimum time light is activated for prior to
closing
0
25.5
0
0.1
Sec
5