The informat ion conta ined in th is docu ment is the property of Automat ic Syst ems and is conf ident ial. The rec ip ient is forb idd en to use it for any purpose ot her
than for the use of the products or the exe cut ion of the project to wh ich th ey refer or to communicate it to th ird parties w ithout the pr ior wr itten conse nt of
Automat ic Systems. Document sub ject to change w ithout advance not if icat ion .
SL93x + TBV327-MT-EN
p. 31/40
Parameter
Range of
values
Default
value
Description
TEST
Inputs
Outputs
Open/Close
INPUTS
:
Tests all the gate inputs. Exit by
pressing OK. Display of 8 digits on
the screen (abcdefgh), copy of the
input indicator LEDs), corresponding
to the inputs, from left to right:
a-Encoder sensor A (81,ch.4.1. ).
(0= no detection ; 1= detection)
b-Encoder sensor B (82,ch. 4.2. ).
(0= no detection ; 1= detection)
c-Locking
(0=unlocked;1=locked with hold
magnet engaged)
d-FIRE
(0=Normal operation ; 1= FIRE)
e-Locking zone (sensor 75, p 16)
(0= detection ; 1= no detection)
f-Clockwise opening request
(0=input activated;1= deactivated)
g-Anti-clockwise opening request
(0=input activated;1= deactivated)
h-Limited opening request
(0=input activated;1= deactivated)
OUTPUTS
:
Successive activation of the 9 gate
outputs for 2 seconds (the red
indicator LEDs illuminate
successively):
- main electromagnet,
- hold magnet,
- anti-clockwise motor,
- clockwise motor,
- low/high speed,
- open/close speed,
- passage active,
- alarm,
- buzzer.
OPEN/CLOSE
: Permanently perform
clockwise and anti-clockwise
opening cycles.
Exit the mode by pressing and
holding OK during the closing of the
anti-clockwise cycle.