The informat ion conta ined in th is docu ment is the property of Automat ic Syst ems and is conf ident ial. The rec ip ient is forb idd en to use it for any purpose ot her
than for the use of the products or the exe cut ion of the project to wh ich th ey refer or to communicate it to th ird parties w ithout the pr ior wr itten conse nt of
Automat ic Systems. Document sub ject to change w ithout advance not if icat ion .
SL93x + TBV327-MT-EN
p. 25/40
With the obstacle in its locked position (
bolt
21
engaged into a hole), the
contact plate (34)
must lie on the
hold magnet (35)
.
Check that the
electro-magnet core (31)
does
not touch the steel frame; if so, move the
complete bolt assembly away from the frame.
Fix the bolt assembly to the plate by tightening
screws (30)
.
In the locked position (activate the bolt by
pushing
core (31)
and not
contact plate (34)
!),
adjust the
bolt (21)
until it is as far as possible
into the hole: the contact plate (34) must
smoothly lie on hold magnet (35), without
forcing. If not the case, adjust the hold magnet
support height by means of the
screws (38)
.
Check the same adjustment for the 2 remaining
locking holes.
Fix the bolt (21) by firmly tightening
nut (36)
.
Fit the
return spring (37)
.
Adjust the centering of contact plate (34) with
respect to hold magnet (35) by carefully bending
the contact plate’s arm.
Connect the red cable to the contact plate
exactly as shown in the picture.
The cable must be not snag during the
movement of contact plate (34).
34
35
31
frame
38
36
37
34
35