Parameter
Range of
values
Default
value
Description
OPENING ANGLE
ANTI-CLOCKW ISE
0 to 180°
Accordi ng to the
"90°/rotati on"
para meter:
respectively
90°/ 120°
Fine adjustment of the maximum
opening angle in the anti-clockwise
direction, selected at parameter
"90°/Rotative".
This adjustment may be necessary
according to obstac
le’s height.
Note
: adjust the limit stops after
modifying this parameter (ch.5.7. ).
START TIME AFTER
BADGE
0 to 200
(in 0.1 s)
0
Time delay between an open
command (badge, pushbutton, etc.)
and the actual unlocking.
STOP TIME IN 90°
MODE
0 to 100 s
4
Only applicable for a Swing Gate
(not for TBV): stop time in the open
position before closing.
FAULT TIMER
0 to 30 s
10
Maximum time allowed for the
obstacle to complete its movement
(from closed to open or vice versa).
Note
: Consequently the value set
must be
slightly
(*)
higher than the
necessary time for the obstacle to
complete the movement under
normal conditions (depending on the
selected speeds: refer to "High
speed" and "Low speed"
parameters).
(*)
Slightly higher because the motor
forces against the obstruction and
overheats during the delay set here.
Note
: the Opening angle must be
adjusted so that the obstacle
reaches it before being stopped by
the limit stops (cf. ch.5.7. ).
HSP > LSP ANGLE
OPENING
0 to 90°
Accordi ng to the
"90°/rotati on"
para meter,
respecti vel y
70°/ 95°
Fine adjustment of the angle at
which the obstacle switches from
high speed to low speed during
opening.
Adapt according to obstacle height:
the higher it is, the higher its inertia
and the earlier the speed must be
decreased to it stop at the desired
position.
HSP > LSP ANGLE
CLOSING
0 to 90°
Accordi ng to the
"90°/rotati on"
para meter,
respecti vel y
35°/ 35°
Fine adjustment of the angle at
which the obstacle switches from
high speed to low speed during
closing.
Adapt according to obstacle height:
the higher it is, the higher its inertia
and the earlier the speed must be
decreased to stop it at the desired
position.