Automatic Systems
Logic D1 v06-02-en0802.doc
ERB-PM
Technical manual
26/31
X3
(
8:2
): The Outputs
Terminal 61 is a 24V DC output from the board AS1200 and is limited to 150mA.
Terminal
Use
61
24V 150mA max.
62
Ground
63
Boom lighting
64
Ground
65
Electromagnet of the electromagnetic tip support or
Solenoid of the electromechanical tip support
66
Relay 1 NO
67
Relay 1 Common
68
Relay 2 NO
69
Relay 2 Common
3.4.2.
The switch SW3
DIP N°
Function
OFF
ON
1
Selection between 1 or 2 traffic lights
1 traffic light
2 traffic lights
2
Traffic light operation direction (if only one)
Entry (OVB)
Exit (DPO)
3
Green authorisation light (if only one)
Continuous
Blinking
4
Red light changeover
After loop
On loop
5
Electromagnetic tip support into service
Disable
Enable
6
Electromechanical tip support in operation
Disable
Enable
7
Boom lighting
Blinking
Continuous
8
Detection of the presence of the boom
Disable
Enable
3.4.3.
Lighting
When lit green, the LED’s have the following functions:
LD1
Entry command OVB in direction A
LD2
Entry command OVB in direction B
LD3
Presence of the boom in the electromechanical tip support
LD4
Activation of the bolt of the electromechanical tip support
LD5
Indication of boom lighting
LD6
Control of electromagnetic tip support
LD7
REL1 engaged
LD8
REL2 engaged