Automatic Systems
Logic D1 v06-02-en0802.doc
ERB-PM
Technical manual
11/31
2.4.
Programming.
2.4.1.
Parameters.
Programming stored in the
EEPROM
defines the time-out parameters, the restart mode after out of order
status (HS), the functions of the information relays, the choice of sensors for counting, etc.
No commands will be active during programming.
PRAMETERS CHART
Nr
Name
Unit
Mini-
Maxi
Default
Remarks
1
Movement time-out
1s
1-30
30
If the FCO or the FCF are not achieved within the programmed
period, the barrier places itself HS (Out of order).
2
No-passage time-out
1s
0 or
5-120
0
This time-out is activated on opening of the barrier.
The barrier closes at the end of the programmed period.
Set the value to 0 to cancel this time-out.
3
Time-out after passage or
after closing command.
1s
0
or
1-10
0
The count-down to the closing of the barrier start after:
leaving a presence sensor (DP)
a manual closing command
a BLQF command without sensor.
Also used to activate a revolving light before the closing
movement.
4
Intensive test time-out
1s
1-10
1
Pause between each operation command for the intensive
test.
5
Motor inversion time-out
100ms
1-50
3
Pause before reversing of the barrier movement.
6
Restart mode after HS
(out of order)
0 or 1
1
In 0 mode, the HS is permanent and the logic board must be
reset by shutting down and restart the power supply.
In mode 1, the barrier restarts with the opening command.
7
Time-out before OVB
(for electromagnetic tip
support)
100ms
1-50
6
This time-out determines the time between demagnetisation of
the tip support and opening of the barrier.
Also used to activate a revolving light before the opening of
the barrier.
8
Relay functions
AS1220
1-3
1
1. Passage traffic lights associated to the obstacle.
2.
Information copy-out on dry NO contacts (par. 9 and 10).
3. Master-slave: controls another barrier.
9
Choice of information to
be copy-out by
REL1
AS1220
1-20
1
1. DP1
2. DP2
3. DP3
4. DP4
5. OVB command
6. FRB command
7. STOP command
8. BLQO command
9. BLQF command
10. Barrier status
11. Revolving light
12. FCO
13. FCF
14. crank FC
15. HS
16. Arm swing-off
17. Passage 1 direction 1
18. Passage 1 direction 2
19. Passage 2 direction 1
20. Passage 2 direction 2