ERB-PM
Technical manual
12/31
10
Choice of information to
be copy-out by
REL2
AS1220
1-20
2
1. DP1
2. DP2
3. DP3
4. DP4
5. OVB command
6. FRB command
7. STOP command
8. BLQO command
9. BLQF command
10. Barrier status
11. Revolving light
12. FCO
13. FCF
14. crank FC
15. HS
16. Arm swing-off
17. Passage 1 direction 1
18. Passage 1 direction 2
19. Passage 2 direction 1
20. Passage 2 direction 2
11
Choice of information to
be copy-out by
REL1
AS1200
1-20
10
1. DP1
2. DP2
3. DP3
4. DP4
5. OVB command
6. FRB command
7. STOP command
8. BLQO command
9. BLQF command
10. Barrier status
11. Revolving light
12. FCO
13. FCF
14. crank FC
15. HS
16. Arm swing-off
17. Passage 1 direction 1
18. Passage 1 direction 2
19. Passage 2 direction 1
20. Passage 2 direction 2
12
Choice of information to
be copy-out by
REL2
AS1200
1-20
11
1. DP1
2. DP2
3. DP3
4. DP4
5. OVB command
6. FRB command
7. STOP command
8. BLQO command
9. BLQF command
10. Barrier status
11. Revolving light
12. FCO
13. FCF
14. crank FC
15. HS
16. Arm swing-off
17. Passage 1 direction 1
18. Passage 1 direction 2
19. Passage 2 direction 1
20. Passage 2 direction 2
13
Power failure mode
Activated by the DIP 4 of
the operation parameters
0 or 1
0
0: Opening command together when powering on.
1: for barriers with a variable speed controller, the barrier will
be unlocked in case of power failure.
14
Choice of the 2 sensors
(DP) for the 2 directions of
the passage 1
1, 2, 3
or 4
The 2 sensors are chosen by means of the first DIP-switches
of SW4: DIP1 for DP1, DIP2 for DP2, DIP3 for DP3 and DIP4
for DP4.
15
Choice of the 2 sensors
(DP) for the 2 directions of
the passage 2
1, 2, 3
or 4
The 2 sensors are chosen by means of the first DIP-switches
of SW4: DIP1 for DP1, DIP2 for DP2, DIP3 for DP3 and DIP4
for DP4.
2.4.2.
Information of the relays
The choice of information on relays 1 and 2 of boards AS1200 and AS1220 are as follows:
1.
DP1
copies the status of the sensor 1 (connected in X7
↑
; 21-22).
2.
DP2
copies the status of the sensor 2 (connected in X7
↑
; 19-20).
3.
DP3
copies the status of the sensor 3 (connected in X7
↓
; 43-44).
4.
DP4
copies the status of the sensor 4 (connected in X7
↓
; 41-42).
5.
OVB
copies the status of the inputs OVB (opening commands)
6.
FRB
copies the status of the inputs FRB (closing commands)
7.
STOP
copies the status of the inputs STOP
8.
BLQO
copies the status of the input BLQO
9.
BLQF
copies the status of the input BLQF
10.
Barrier status
The relay chosen with this function engage with the opening command of the
barrier and loosen with the closing command.