9-8
FITTED EQUIPMENT
TRUMA ULTRASTORE WATER
HEATER
The Truma Ultrastore is a liquid gas operated
storage water heater with an additional 230V
electric heating element. It is fitted in the
base of the kitchen cupboard adjacent to the
bathroom and is identified by an external
cowl.
Operating Instructions
Always observe the operating instructions
prior to starting. The owner is responsible for
the correct operation of the appliance.
A yellow sticker with the warning information
is fitted to the wardrobe door. Read this
before use.
WARNING: Always mount the cowl cap
when the water heater is not being
operated and drain the water heater if
there is a risk of frost. Claims under
guarantee for damage caused by frost,
cannot be accepted either by ourselves or
Truma.
WARNING: In the event of changing the
water pump with one of a different type,
ensure that a pressure of 2.8 bar is not
exceeded. We recommend the Shurflo
water pump model Trailking 7.
e = Lever position ‘closed’
f
= Lever position ‘drain’
Filling the Truma Ultrastore with Water
1.
Check that the safety/drain valve in the
cold water intake is closed: Lever should
be in horizontal position, position (e).
2.
Open hot tap in bathroom or kitchen, with
pre-selecting mixing taps or single-lever
fittings to “hot”.
3.
Switch on water pump on electrical
control panel.
4.
Leave the tap open to let air escape
while the water heater is filling. The
heater is filled when water flows out of
the tap.
Residues of frozen water can prevent filling if
there is a frost. The water heater can be
defrosted by switching on the heater for a
short period (max 2 minutes).
Note:
If just the cold water system is being
used, without the water heater, the heater
tank is also filled up with water. In order to
avoid damage through frost, the water
contents must be drained by actuating the
safety/drain valve and also when the heater
has not been used. As an alternative, a shut-
off valve can be installed upstream of the
cold and hot water connection (your Auto-
Sleeper dealer will advise you on this).
Draining the Water Heater
1.
Disconnect power for water pump by
switching off the water pump switch.
2.
Open hot water taps in the kitchen and
the bathroom.
3.
Open safety/drain valve; with lever in
vertical position, (position f).
The water heater can now be drained directly
to the outside via the safety/drain valve.
Check that the water contents have been
completely drained (approximately 10 litres).
Содержание Gloucester2010
Страница 2: ...DATA RECORD ...
Страница 12: ...2 4 MOTORHOME CODE ...
Страница 18: ...5 2 ARRIVAL AT SITE ...
Страница 52: ...7 26 CONNECTION OF SERVICES 12V 230V WIRING DIAGRAM ...
Страница 86: ...9 30 FITTED EQUIPMENT ARRANGEMENT OF EQUIPMENT GLOUCESTER ...
Страница 90: ...9 34 FITTED EQUIPMENT NORMAL SEATING ASSEMBLY GLOUCESTER ...
Страница 91: ...9 35 FITTED EQUIPMENT DOUBLE BED ASSEMBLY GLOUCESTER ...
Страница 92: ...9 36 FITTED EQUIPMENT OVER CAB BED ASSEMBLY GLOUCESTER ...
Страница 96: ...9 40 FITTED EQUIPMENT ...
Страница 106: ...11 2 USEFUL INFORMATION Superior craftsmanship within your reach at a dealer near you ...
Страница 118: ...13 2 NOTES Designed and Printed by Preset Graphics Tel 01332 2549278 MY 2010 Ref 21140 HB1067 10 ...