7-23
CONNECTION OF SERVICES
5.2 Common Fault Table
Fault
Possible Cause
Proposed Fix
No 230 volt
Connecting lead between
Check and connect lead as per 5.1C.
output from
the site and Leisure
Check also input connector at the base of the EC325PSU.
PSU.
Vehicle not connected.
RCD switched off.
Reset RCD as per 5.1D.
RCD not operating
Check supply polarity; if the RCD continues to fail contact your
correctly.
dealer, as there is probably an equipment or wiring fault.
MCB switched off.
Reset MCB by switching OFF (down position) then back ON (up
position), if the MCB continues to fail contact your dealer, as there is
probably an equipment or wiring fault.
No or deficient supply
Contact site warden for assistance.
from site.
Other fault.
Contact your dealer.
Reverse Polarity
Mains Supply reversed?
The reverse polarity light is designed to illuminate when the Live and
light is illuminated
.
Neutral supply has been reversed/crossed over. If the light illuminates
on PSU
there is a problem with the site supply or the cable connecting the supply
to your vehicle. The light is designed to work on UK electrical supplies
(where the neutral conductor is connected to earth at the sub stattion). If
you are using your vehicle outside the UK this light may illuminate when
no fault axists. In these cases consult the site warden for advice.
Generator being used
The Reverse Polarity warning light is on when using my generator.
This is a normal side effect when using some types of generator. Instead
of connecting the neutral conductor to earth, some generators centre tap
the earth connection making both neutral and live conductors 110V
above earth. This 110V difference causes the neon polarity indicator to
illuminate. In most cases it is still safe to use the generator, but please
consult the generator handbook for further information.
Control Panel
Control Panel has no display
Check batteries, turn EC325PSU charger switch on, and ensure mains
Problems
supply is connected.
Check control panel connecting lead at EC325PSU and behind
Control Panel.
Contact your Dealer.
12V Power turns off
Battery save feature has operated to protect the vehicle battery and or
the Leisure battery. See 3.7C.
Engine has been started, all equipment has been disconnected to meet
EMC requirements. See 4.4.
Control Panel display
Observe control panel handling instructions.
corrupt/erratic function
Control panel software may have crashed. Reboot control panel by
turning off the EC325PSU charger switch and removing fuses 1 & 2
at the EC325PSU (2x20A fuses for leisure and vehicle batteries).
Wait 30 seconds then replace the fuses and turn the charger switch on.
(Alternatively, remove the bezel at the control panel by pulling down
in the centre of the bottom, unplug the control panel multi-way
connector, wait 30 seconds, then plug back in and reassemble.
Control Panel contrast poor
Observe control panel handling instructions.
Remove control panel as above but do not unplug. Carefully adjust
contrast preset (small adjuster) on back of control panel using
jewellers screwdriver.
Содержание Gloucester2010
Страница 2: ...DATA RECORD ...
Страница 12: ...2 4 MOTORHOME CODE ...
Страница 18: ...5 2 ARRIVAL AT SITE ...
Страница 52: ...7 26 CONNECTION OF SERVICES 12V 230V WIRING DIAGRAM ...
Страница 86: ...9 30 FITTED EQUIPMENT ARRANGEMENT OF EQUIPMENT GLOUCESTER ...
Страница 90: ...9 34 FITTED EQUIPMENT NORMAL SEATING ASSEMBLY GLOUCESTER ...
Страница 91: ...9 35 FITTED EQUIPMENT DOUBLE BED ASSEMBLY GLOUCESTER ...
Страница 92: ...9 36 FITTED EQUIPMENT OVER CAB BED ASSEMBLY GLOUCESTER ...
Страница 96: ...9 40 FITTED EQUIPMENT ...
Страница 106: ...11 2 USEFUL INFORMATION Superior craftsmanship within your reach at a dealer near you ...
Страница 118: ...13 2 NOTES Designed and Printed by Preset Graphics Tel 01332 2549278 MY 2010 Ref 21140 HB1067 10 ...