Installation Manual 

 200E Series  

Page 4 

 

Installation 

Installation covers panel location, 

wiring and first power-on. 

Panel location 

This section gives basic guidelines for 

installing the different panels.  

DCU 210E 

The panel is normally located in the 

engine room for a number of reasons. 

  

 

The main reasons are:  

 

Local operation and overview. 

 

Minimize cabling requirements 

and cost from sensors to panel. 

 

Reduce of electrical noise levels 

resulting from long cables. 

DCU 208E 

This panel is also normally installed in 

the engine room, close to the engine.  

Unlike the DCU 210E and the RP 

210E/220E the DCU 208E is installed 

on a din-rail.  

The panel does not have a user 

interface and is normally used in 

unmanned engine rooms.  

A RP 210E/220E remote panel is used 

to bring the signals from the engine 

room to a monitoring site, e.g. bridge 

or wheelhouse.  

RP 210E/220E 

The RP remote panel is normally 

located at a remote place away from 

the engine room, but it can also be 

used in the engine room. 

Compatible panel series  

Note that the 200 series panel can be 

used together with the 400 series 

panels.  

For instance can a RP 210E/220E 

remote panel be used to monitor a 

DCU 410 engine panel. 

General  

Panels with a screen should be 

mounted at about eye level and the 

user should have easy access to 

operate the panel. 

Ensure easy access to the rear wiring. 

The panel may be mounted on the 

engines supporting structure provided 

shock absorbers are used either 

between the structure and the engine, 

or between the structure and the panel 

enclosure.  

 

 

Содержание Marine Pro DCU 208E

Страница 1: ...Manual 1006495 Installation Manual 200E Series DCU 210E 208E Engine Panel RP 210E 220E Remote Panel...

Страница 2: ...ge 6 1 3 15 2 2016 Added connections drawing page 12 1 4 18 3 2016 Thermistor 2 3 and 4 wire drawings 1 5 25 11 2016 RP 220E added 1 6 25 09 2017 Added installation notes released to Ethernet and swit...

Страница 3: ...eries 4 General 4 Panel Cut out 5 Mounting bracket 5 CONNECTORS 5 Connector kit 5 Connector pinout DCU 210E and 208E 6 Connector pinout RP 210E 220E 7 WIRING CONNECTIONS 8 General 8 Grounding 8 Power...

Страница 4: ...ctorily manner that it is operationally in good order that the approved material and accessories are used and that the installation meet all applicable rules and regulations Note Auto Maskin continuou...

Страница 5: ...Engine Panel The DCU 208E is basically the same as the DCU 210E but without the color touch screen It saves cost being used in smaller engine rooms where a remote panel is all that is needed Configura...

Страница 6: ...ecommended to make use of an Ethernet switch though as it simplifies PC configuration connection and future expansion to remote panels and or camera interface Note For redundant Ethernet connection ma...

Страница 7: ...rface and is normally used in unmanned engine rooms A RP 210E 220E remote panel is used to bring the signals from the engine room to a monitoring site e g bridge or wheelhouse RP 210E 220E The RP remo...

Страница 8: ...nstalled with the mounting bracket shown in grey Connectors DCU 210E DCU 208E RP 210E and RP 220E These are the connectors on the DCU and RP back lid The DCU 208E front view is the same as the DCU 210...

Страница 9: ...1 C2P4 NC C2P5 Common C2P6 NO On Board Relay 2 C2P7 NC C2P8 Common C2P9 NO Magnetic Pickup C4P1 A In C4P2 B I O 181 In Modbus RTU RS 485 C4P3 Shield In C4P4 Low In C4P5 High In Thermistor Input C4P6...

Страница 10: ...nector is described as e g C1P2 Where 1 is the connector number and 2 is the pin number Power Supply C1P11 12 24VDC Primary Supply In Out C1P12 0V Primary Supply In C1P3 Ground connection In Switch In...

Страница 11: ...he system Note Please keep ground and 0V separated If ground and 0V is connected these filters do not work properly Power Supply C1P11 C1P12 The 200E Series is designed to run on either 12 VDC or 24 V...

Страница 12: ...A fault is defined as any new instance in the alarm list except diagnostic messages graded white The relay has a 1 A over current protection on the common pin Relay 1 C2P4 C2P6 This relay can be confi...

Страница 13: ...can be configured as configurable 12 24V outputs on the DCU Each channel can be configured for any available function Voltage Sensor Input All flexible I O can be configured as voltage sensor inputs o...

Страница 14: ...erface This interface is used for two purposes Update of the current configuration file not RP panels Update the panel firmware all panels Copy a valid configuration and or firmware file to a USB memo...

Страница 15: ...Installation Manual 200E Series Page 12 Appendix A Typical sensor connections DCU 210E...

Отзывы: