Installation Manual 

 200E Series  

Page 6 

 

Connector pinout 

  

DCU 210E and 208 E 

The table below shows the connector 

pinout on the DCU panels. 

 

The connector is described as e.g. 

C1P2. Where 1 is the connector 

number and 2 is the pin number. 

See 

Appendix A

 to see typical sensor 

connections DCU 210E. 

 

Power Supply 

C1P11 

+12/24VDC Primary Supply 

In/Out 

C1P12 

0V Primary Supply 

In 

C1P3 

Ground connection 

In 

RIO Link Interface 

C1P5 

Low 

In 

C1P6 

High 

In 

CAN J1939 Engine Interface 

C1P7 

CAN 1High 

In 

C1P8 

CAN 1 Low 

In 

C1P9 

CAN 1 Shield 

In 

C2P10 

CAN 2 High - (I/O #20

3

In 

C2P11 

CAN 2 Low - (I/O #21

3

In 

C2P12 

CAN 2 Shield - (I/O #5) 

In 

All Faults Relay (Inactive on fault) 

C2P1 

NC 

C2P2 

Common 

C2P3 

NO 

On Board Relay #1 

C2P4 

NC 

C2P5 

Common 

C2P6 

NO 

On Board Relay #2 

C2P7 

NC 

C2P8 

Common 

C2P9 

NO 

Magnetic Pickup 

C4P1 

In 

C4P2 

B - (I/O #18

1

In 

Modbus RTU, RS-485 

C4P3 

Shield 

In 

C4P4 

Low 

In 

C4P5 

High 

In 

Thermistor Input 

C4P6 

Thermistor #1 A 

In 

C4P7 

Thermistor #1 B 

In 

C4P8 

Thermistor #1 C 

In 

C4P9 

Thermistor #2 A 

In 

C4P10 

Thermistor #2 B 

In 

C4P11 

Thermistor #2 C 

In 

Flexible I/O 

C1P1 

I/O #1 

In/Out 

C1P2 

I/O #2

In/Out 

C1P4 

I/O #3 

In/Out 

C1P10 

I/O #4

 

In/Out 

C2P12 

I/O #5

In/Out 

C3P1 

I/O #6

2

 / Sensor Power 

In/Out 

C3P2 

I/O #7 

In/Out 

C3P3 

I/O #8 

In/Out 

C3P4 

I/O #9 

In/Out 

C3P5 

I/O #10 

In/Out 

C3P6 

I/O #11 

In/Out 

C3P7 

I/O #12

In/Out 

C3P8 

I/O #13 

In/Out 

C3P9 

I/O #14 

In/Out 

C3P10 

I/O #15 

In/Out 

C3P11 

I/O #16 

In/Out 

C3P12 

I/O #17 

In/Out 

C4P2 

I/O #18

In/Out 

C4P12 

I/O #19 

In/Out 

 

1

Configurable as flexible I/O or as a 0V 

reference.

 

2

Configurable as flexible I/O or supply for 0-

5V sensors. 

3

Alternative I/O function is digital input only. 

Содержание Marine Pro DCU 208E

Страница 1: ...Manual 1006495 Installation Manual 200E Series DCU 210E 208E Engine Panel RP 210E 220E Remote Panel...

Страница 2: ...ge 6 1 3 15 2 2016 Added connections drawing page 12 1 4 18 3 2016 Thermistor 2 3 and 4 wire drawings 1 5 25 11 2016 RP 220E added 1 6 25 09 2017 Added installation notes released to Ethernet and swit...

Страница 3: ...eries 4 General 4 Panel Cut out 5 Mounting bracket 5 CONNECTORS 5 Connector kit 5 Connector pinout DCU 210E and 208E 6 Connector pinout RP 210E 220E 7 WIRING CONNECTIONS 8 General 8 Grounding 8 Power...

Страница 4: ...ctorily manner that it is operationally in good order that the approved material and accessories are used and that the installation meet all applicable rules and regulations Note Auto Maskin continuou...

Страница 5: ...Engine Panel The DCU 208E is basically the same as the DCU 210E but without the color touch screen It saves cost being used in smaller engine rooms where a remote panel is all that is needed Configura...

Страница 6: ...ecommended to make use of an Ethernet switch though as it simplifies PC configuration connection and future expansion to remote panels and or camera interface Note For redundant Ethernet connection ma...

Страница 7: ...rface and is normally used in unmanned engine rooms A RP 210E 220E remote panel is used to bring the signals from the engine room to a monitoring site e g bridge or wheelhouse RP 210E 220E The RP remo...

Страница 8: ...nstalled with the mounting bracket shown in grey Connectors DCU 210E DCU 208E RP 210E and RP 220E These are the connectors on the DCU and RP back lid The DCU 208E front view is the same as the DCU 210...

Страница 9: ...1 C2P4 NC C2P5 Common C2P6 NO On Board Relay 2 C2P7 NC C2P8 Common C2P9 NO Magnetic Pickup C4P1 A In C4P2 B I O 181 In Modbus RTU RS 485 C4P3 Shield In C4P4 Low In C4P5 High In Thermistor Input C4P6...

Страница 10: ...nector is described as e g C1P2 Where 1 is the connector number and 2 is the pin number Power Supply C1P11 12 24VDC Primary Supply In Out C1P12 0V Primary Supply In C1P3 Ground connection In Switch In...

Страница 11: ...he system Note Please keep ground and 0V separated If ground and 0V is connected these filters do not work properly Power Supply C1P11 C1P12 The 200E Series is designed to run on either 12 VDC or 24 V...

Страница 12: ...A fault is defined as any new instance in the alarm list except diagnostic messages graded white The relay has a 1 A over current protection on the common pin Relay 1 C2P4 C2P6 This relay can be confi...

Страница 13: ...can be configured as configurable 12 24V outputs on the DCU Each channel can be configured for any available function Voltage Sensor Input All flexible I O can be configured as voltage sensor inputs o...

Страница 14: ...erface This interface is used for two purposes Update of the current configuration file not RP panels Update the panel firmware all panels Copy a valid configuration and or firmware file to a USB memo...

Страница 15: ...Installation Manual 200E Series Page 12 Appendix A Typical sensor connections DCU 210E...

Отзывы: