Installation Manual 

 200E Series  

Page 5 

 

Panel Cut -out 

The DCU and RP cut-out size is: 

 

153mm width, 123 mm height 

Mounting bracket 

DCU 210E and RP 210E/220E 

When installing the panel make sure to 

use the bundled screws and mounting 

bracket.   

If installing the panel on a thicker 

surface than 5mm, longer flanged 

screws must be used. In this case M3 

16mm flanged screws is 

recommended. 

Make sure that the screws are not too 

long, as this will damage the panel. 

  

The DCU 210E / RP 210E installed with the 
mounting bracket shown in grey. 

Connectors 

DCU 210E, DCU 208E, RP 210E 
and RP 220E 

These are the connectors on the DCU 

and RP back lid.  

 

The DCU 208E front view is the same as the 
DCU 210E rear view. 

Connector kit 

The 200E series is not shipped with 

mating connectors. 

A complete kit is available containing 

all of the mating terminal blocks used 

on the 200 E series.  

Kit 1006479 contains: 

 

4 Deutsch DT series connectors 

(DT06-12SA). 

 

50 hand crimp sockets 0.5 -1.0 

mm

2

  (16-20 AWG). 

 

10 hand crimp sockets 1.0 -2.0 

mm

2

  (14-16 AWG). 

 

50 sealing plugs for unused 

terminals. 

A crimp tool is necessary for 

proper crimping of the mating 

terminals. Use Deutsch HDT-48-00 

crimping tool. 

Содержание Marine Pro DCU 208E

Страница 1: ...Manual 1006495 Installation Manual 200E Series DCU 210E 208E Engine Panel RP 210E 220E Remote Panel...

Страница 2: ...ge 6 1 3 15 2 2016 Added connections drawing page 12 1 4 18 3 2016 Thermistor 2 3 and 4 wire drawings 1 5 25 11 2016 RP 220E added 1 6 25 09 2017 Added installation notes released to Ethernet and swit...

Страница 3: ...eries 4 General 4 Panel Cut out 5 Mounting bracket 5 CONNECTORS 5 Connector kit 5 Connector pinout DCU 210E and 208E 6 Connector pinout RP 210E 220E 7 WIRING CONNECTIONS 8 General 8 Grounding 8 Power...

Страница 4: ...ctorily manner that it is operationally in good order that the approved material and accessories are used and that the installation meet all applicable rules and regulations Note Auto Maskin continuou...

Страница 5: ...Engine Panel The DCU 208E is basically the same as the DCU 210E but without the color touch screen It saves cost being used in smaller engine rooms where a remote panel is all that is needed Configura...

Страница 6: ...ecommended to make use of an Ethernet switch though as it simplifies PC configuration connection and future expansion to remote panels and or camera interface Note For redundant Ethernet connection ma...

Страница 7: ...rface and is normally used in unmanned engine rooms A RP 210E 220E remote panel is used to bring the signals from the engine room to a monitoring site e g bridge or wheelhouse RP 210E 220E The RP remo...

Страница 8: ...nstalled with the mounting bracket shown in grey Connectors DCU 210E DCU 208E RP 210E and RP 220E These are the connectors on the DCU and RP back lid The DCU 208E front view is the same as the DCU 210...

Страница 9: ...1 C2P4 NC C2P5 Common C2P6 NO On Board Relay 2 C2P7 NC C2P8 Common C2P9 NO Magnetic Pickup C4P1 A In C4P2 B I O 181 In Modbus RTU RS 485 C4P3 Shield In C4P4 Low In C4P5 High In Thermistor Input C4P6...

Страница 10: ...nector is described as e g C1P2 Where 1 is the connector number and 2 is the pin number Power Supply C1P11 12 24VDC Primary Supply In Out C1P12 0V Primary Supply In C1P3 Ground connection In Switch In...

Страница 11: ...he system Note Please keep ground and 0V separated If ground and 0V is connected these filters do not work properly Power Supply C1P11 C1P12 The 200E Series is designed to run on either 12 VDC or 24 V...

Страница 12: ...A fault is defined as any new instance in the alarm list except diagnostic messages graded white The relay has a 1 A over current protection on the common pin Relay 1 C2P4 C2P6 This relay can be confi...

Страница 13: ...can be configured as configurable 12 24V outputs on the DCU Each channel can be configured for any available function Voltage Sensor Input All flexible I O can be configured as voltage sensor inputs o...

Страница 14: ...erface This interface is used for two purposes Update of the current configuration file not RP panels Update the panel firmware all panels Copy a valid configuration and or firmware file to a USB memo...

Страница 15: ...Installation Manual 200E Series Page 12 Appendix A Typical sensor connections DCU 210E...

Отзывы: