400 Series Installation and Configuration
RP 410 Remote Panel Installation
93
DCU Alarms
If disabled, no alarms will be present on this RP station.
This is typically use in the wheelhouse, if there is another
RP panel in a manned engine control room.
DCU Acknowledge
If disabled, alarms cannot be acknowledged on this RP
station.
Note! If DCU Alarms is disabled then DCU Acknowledge is
also disabled.
Station Location
Select the current location for this panel.
This is used in conjunction with multiple RP remote
panels, where there is a need for the other panels to see
which panel is asking to become the active station for a
certain engine.
Functional Outputs
If the optional relay board module MK-14 is connected to
the RP port COM 5, certain functions can be configured to
appear at these relays.
See page 108 for a closer description of the MK-14
module.
IP-address
The IP-address for the RP can be changed here.
Note! Make sure the new IP-address is unique on the
network.