![Autarco OX Series Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/autarco/ox-series/ox-series_installation-and-operation-manual_3020188034.webp)
I_DC20 %VALUE% A
Shows the input current (A) of the DC input 20
7.4 Settings
The following options are available under the Settings submenu:
Set Time and Date
Press UP/DOWN keys to set change element
Press ENTER key to move to next element
Press ESC key to save date and return
Set Address
Assign a number (##) to the inverter to distinguish between multiple inverters when
using parallel communication with WIFI-BOX or GPRS-BOX
Press UP/DOWN keys to set change number
Press ENTER key to save the setting
Press ESC key to return.
Changing the Address when using WIFI-STICK or LAN-STICK may
result in monitoring to stop working.
7.5 Advanced info
WARNING! Access to this section of the menu is for Autarco qualified and accredited
technicians only. Unauthorized access will void the product and system warranty.
Screen can be scrolled through with UP/DOWN keys to see the information as per the table below.
Press ENTER key to enter a submenu. Press ESC key to go back to the main menu.
Alarm Messages
The display shows the 100 latest alarm messages (see Figure 7.6).
Press UP/DOWN keys to cycle through alarm messages
Press ESC key to return
Running Message
This function is for maintenance personnel to get running message such as
internal temperature, Standard NO. etc.
Screens can be scrolled manually by pressing the UP/DOWN keys.
Version
The screen shows the operating software version of the inverter
Daily Energy
The function is for checking the energy generation for selected day.
Press DOWN key to move the cursor to day, month and year, press UP key to
change the digit.
Press ENTER after the date is fixed.
Press UP/DOWN key to move one date from another.
Monthly Energy
The function is for checking the energy generation for selected month.
Press DOWN key to move the cursor, press UP key to change the digit.
34
OX-series Inverters