![Autarco OX Series Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/autarco/ox-series/ox-series_installation-and-operation-manual_3020188014.webp)
5 Installation
5.1 Safety
DANGER! Do not install the inverter near flammable or explosive items.
WARNING! The installation must be performed by qualified personnel and in
compliance with national and local standards and regulations. This inverter will be
connected to a high voltage DC power generator and AC grid. Inappropriate
installation may also jeopardize the life span of the inverter.
The installation site must have good ventilation conditions. Direct exposure to
intense sunshine is not recommended.
5.2 Appropriate mounting location
The heat sink can reach a temperature of 75⁰C under operation.
Location and environmental requirements:
●
Make sure the mounting wall is strong enough to hold the weight of the inverter.
●
The ambient temperature of the installation site should be between -25 ⁰C and +60 ⁰C.
●
Make sure of sufficient ventilation at installation site; insufficient ventilation may reduce
the performance of the electronic components inside the inverter and shorten the lifespan
of the inverter.
●
The inverter has fans that will intelligently cool the inverter if the internal components
exceed 100⁰C. The fan noise can exceed 50dB; installation is not recommended in public
areas.
14
OX-series Inverters