![Autarco OX Series Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/autarco/ox-series/ox-series_installation-and-operation-manual_3020188026.webp)
shrinkable tube or insulating tape. When using the heat shrinkable tube, sleeve the heat
shrinkable tube over the wire before crimping the OT terminal.
NOTE: If chosing aluminum alloy cable, you must use a copper aluminum transfer
terminal in order to avoid direct contact between the copper bar and the aluminum
alloy cable. (Please select a copper aluminum transfer terminal based on your cable
specification.)
3. Leave the AC breaker disconnected to ensure it does not close unexpectedly\
4. Remove the 4 screws on the AC terminal cover and remove the cover.
5. Remove the screw under the terminal slide and pull out the terminal.
26