Id.Nr.: 229224-9 •
9
District heating tank FSN and FSN-E
9. Adjustment Range Limitation FSN-E F
To avoid accidental scalding by water that is too
hot, the adjustment range of the temperature
regulator can be limited to a max. of 65 °C.
The
device must be electrically isolated from the
grid at all poles.
Set to "Pos
➊
". After open-
ing the connection space, remove the stop pin
in that is located in a drilling in the back of the
control panel and reinsert it into the hole with the
long shaft in front.
10. Operating Requirements
B F
The storage tanks must be used exclusively in accordance with the conditions set out on the rating
panel. The maximum input pressure should correspond to the nominal pressure stated on the rating
panel. In addition to the legally recognised national guidelines and standards, the connection condi-
tions of the local electricity and water works as well as those set out in the installation and operating
instructions must be complied with.
The room in which the device is operated must be frost-free. The installation of the device must be carried
out in a place where one might reasonably expect it to be, i.e. the device must be easily accessible in case
of servicing, repairs or in case it needs to be replaced. The hot water storage tank must only be connected
to rigid/fixed plumbing. In the case of hard water, we recommend the installation of a commercial de-calci-
fication device or alternatively we recommend the use of an lime-scale protection storage tank from Austria
Email AG and/or that you run the system at a maximum operating temperature of c.65 °C (set at "Pos
➌
").
In order to prevent the ingress of foreign bodies, the entire device must be professionally flushed out in
accordance with ÖNORM H5195-1 prior to carrying out the initial installation of the district heating stor-
age tank.
In order to prevent the possibility of interference of the district heating storage tank. the electrical devices
used within the household must be ÖVE tested and must comply with EMV guideline 89/336/EWG.
To avoid damage, it is necessary to construct the connection of the storage tank with a detachable con-
nection (union).
Leaks from the storage tank as a result of an improper connection and damage and consequential dam-
age caused by this are excluded from the guarantee and product liability.