 • Id.Nr.: 229224-9

District heating tank FSN and FSN-E

11. Installation and Safety Information 

  F

a) 

Important Installation Information! Do not bend the safety component sus-
pension hooks due to the possibility of breakage. A failure to take notice 
of this warning could result in personal injury due to a falling device!

b)  Every device is delivered with a wall rail for the insertion of the upper securing 

hook, which is attached to the wall with two screws and supports the weight of 
the device. Two additional screw fittings (as per the dimensions sketch with the 
device dimensions) must be provided for affixing the lower tab of the device to 
the wall; this only serves to secure the device against the wall and to prevent 
lateral movement.  Water heaters of a suspended construction type must not be 
installed horizontally.

c)  The securing hooks and therefore the suspension dimension A can be reposi-

tioned  by moving the storage tank rear wall screws into other holes of the 

hook

 in 50 mm spac-

ings.

 

Caution

: Only fixing hooks supplied by AE AG may be used!

d)  During the installation due attention must be paid to device dimension sketches and any informa-

tion signs that may have been supplied together with the device.

e) 

Caution

: The weight of the water heater including the weight of the water content (the nominal 

capacity)  must  be  taken  into  consideration  for  the  selection  of  an  installation  point  and/or  the 
preparation a device mounting surface sufficient to meet the technical loading and installation 
strength requirements.

 

Special Suspension: see narrow wall and/or ceiling mounting.

f) 

If a water heater is fitted with covers (cladding) in narrow small spaces or in suspended ceilings and the like, 
it is crucial to ensure that the connection side of the device (water connections, electrical connection room  
and/or boiler room) remains freely accessible and that heat accumulation is not generated. There 
must be a free space of 500 mm for the dismantling of the heating flange. A space of at least 50 
mm must be left above the device so that it can be hooked into the wall rails.

g)  In terms of the choice and/or sequence of the installation material used on the system side (be 

careful in the case of mixed installation) due consideration must be given to potential electro-
chemical processes (contact corrosion e.g. copper-steel) in accordance with good engineering 
practice. We recommend the installation of insulating screw fixings.

h)  If there is particularly aggressive water, which demands a special solution on the installation side, 

the potential necessity for special constructed versions of the storage tank should be investigated 
(please direct any related questions to our agents or directly to our company).

i)  The device is equipped with a safety temperature limiting device, which prevents any further heat-

ing of the devices beyond a water temperature of 110 °C.  

 

(EN  60335  -2-21;  ÖVE-EW41  ,  Part  2  (500)  /1971).  Therefore  the  choice  of  connection  com-
ponents (connection pipes, circulation, safety valve combinations etc.) should be made in such 
a way that the connection components could withstand temperatures of 110 °C in case of any 
potential malfunction of the temperature regulator and that possible consequential damages 
 are avoided.

j)  The assembly and installation may only be carried out by authorised tradesmen.
k)  There is a risk of scalding under certain operating conditions.

Содержание FSN

Страница 1: ...Operating and Installation Instructions District heating tank FSN and FSN E Please forward this on to the user Id Nr 229224 9...

Страница 2: ...reciate The environmentally friendly CFC free insulating foam ensures an extraordinarily low standby energy consumption For the sake of the environment Austria Email AG s ARA Junk Recy cling Austria A...

Страница 3: ...Dimensions Sketch F 11 13 Special Suspensions B F 12 14 Connection Requirements B F 13 15 District Heating System Connection B F 14 16 Accessories and Plastic Base Installation F 15 17 Domestic Hot Wa...

Страница 4: ...de of polyurethane foam CFC free boiler foam fitted directly into the outer casing Benefit low standby energy consumption Stove enamelled powder coated outer casing of steel plate white Precisely disp...

Страница 5: ...and FSN E Max input power FSN and FSN E at a primary flow volume of 300l h Immediately after warming up the heating circuit is closed so that no further losses are incurred as is usually the case due...

Страница 6: ...umption B F If a water heater is heated up and no water is released for a long time after the heating process an albeit gradual but continuous cooling of the stored water via the surface of the device...

Страница 7: ...ot play with the device 6 Temperature Setting FSN E B F As an aid to setting the temperature the temperature regulator knob has 4 main positions being Position Frost protection for the storage tank up...

Страница 8: ...by the district heating grid wintertime operation 8 Thermometer B F There is a remote thermometer built into the front panel of the device for monitoring the stored water temperature The display value...

Страница 9: ...st be carried out in a place where one might reasonably expect it to be i e the device must be easily accessible in case of servicing repairs or in case it needs to be replaced The hot water storage t...

Страница 10: ...iling mounting f Ifawaterheaterisfittedwithcovers cladding innarrowsmallspacesorinsuspendedceilingsandthelike itiscrucialtoensurethattheconnectionsideofthedevice waterconnections electricalconnectionr...

Страница 11: ...r 229224 9 11 District heating tank FSN and FSN E 12 Dimensions Sketch F Type Con tents Litre Dimensions in mm A B C FSN 110 115 1366 1036 550 800 FSN 140 145 1566 1236 750 1000 FSN 190 195 1900 1570...

Страница 12: ...12 Id Nr 229224 9 District heating tank FSN and FSN E 13 Special Suspension B F Thin wall suspension Ceiling suspension...

Страница 13: ...r Storage Tank 2 Heat Exchanger 3 Back flow Valve 4 Zone Valve 5 Safety Valve 6 Return Flow Inhibitor 7 Dirt Trap 8 Drainage Valve 9 Electric Heating 10 Bleeding Thermostat for electric heating Thermo...

Страница 14: ...ing up temperature via the remote heating circuit is done electrically and the setting is fixed in the factory An additionally installed temperature limiting device prevents overly high back flow temp...

Страница 15: ...Id Nr 229224 9 15 District heating tank FSN and FSN E 16 Accessories and Plastic Base Installation F...

Страница 16: ...spaces The outlet of the safety valve must be open and observable and or the outlet pipe from the drip tray water overflow funnel must not terminate outside so that neither frost nor blockages due to...

Страница 17: ...valve will have to be completely replaced Implementation Installation Company Interval annually To check the back flow valve the shut off valve is closed and no water should escape via the open test...

Страница 18: ...le must be inserted into the connection space of the storage tank and be prevented from being pulled out and twisted by a strain relief mechanism For register storage heaters a second cable insert is...

Страница 19: ...ather season if the device will be out of action for several days and is not being operating in frost protection mode see Point 6 The draining of the domestic water is carried out once the shut off va...

Страница 20: ...heating flange it is crucial to use a new seal The specially enamelled inner container of the water heater must not come into contact with boiler scale solvent do not use the de calcifying pump Remov...

Страница 21: ...ence connecting to incorrect voltage corrosion damage as a consequence of aggressive waters water not suitable for drinking in accordance with the national regulations e g Austrian ordinance on drinki...

Страница 22: ...t if all the regulations standards assembly and operating instructions general guidelines etc are observed the defect in the unit or product causal for occurrence of the secondary damage would not hav...

Страница 23: ......

Страница 24: ...erreich Burgenland A 1230 Wien Zetschegasse 17 Telefon 01 615 07 27 Fax 01 615 07 27 260 E Mail tvondal austria email at Steiermark K rnten Osttirol A 8054 Graz Dr Heschl Weg 6 Telefon 0316 271 869 Fa...

Отзывы: